Chapter 6
Component Guide
DME Designer Owner’s Manual
385
■
Filter Type
Various types of curves are available for changing the level. Click the [Type] button and select the
type from the menu.
• PEQ
This is a general parametric equalizer.
• L. SHELF (Low Shelving)
There is no sound attenuation at low frequencies. The sound is attenuated at a constant rate
from the cutoff frequency towards the higher frequencies. The attenuation rate per octave can
be set to [6 dB/Oct] or [12 dB/Oct].
• H.SHELF (High Shelving)
There is no sound attenuation at high frequencies. The sound is attenuated at a constant rate
from the cutoff frequency towards the lower frequencies. The attenuation rate per octave can
be set to [6 dB/Oct] or [12 dB/Oct].
• HPF
This is a high-pass filter (Q=0.7). Attenuates the low frequencies with a gentle curve (12 dB/
Oct).
• LPF
This is a low-pass filter (Q=0.7). Attenuates the high frequencies with a gentle curve (12 dB/
Oct).
Name
Function
1
EQ Curve
Displays the equalizer effect.
You can change the parameter by dragging
the control point with the mouse.
Section
Parameter
Setting Range
Function
2
Input
Level
-
∞
to +10 dB
Sets the input signal level.
3
Phase
ON/OFF
Reverses the phase of the input signal.
4
Equalizer
Type
PEQ
L.SHELF 6 dB/Oct
L.SHELF 12 dB/Oct
H.SHELF 6 dB/Oct
H.SHELF 12 dB/Oct
HPF
LPF
Select the filter type from the menu.
5
Q
0.1 to 16.0
Sets the band width for each frequency
band.
6
Frequency
20 Hz to 20 kHz
Sets the frequency for each band.
7
Gain
-18 dB to +18 dB
Sets the level of the frequency that will be
changed.
8
Bypass
ON/OFF
Turns ON bypass for each band.
9
Equalizer
PEQ ON
ON/OFF
Turns the PEQ ON
)
Output
Level
-
∞
to ±0 dB
Sets the output signal level.
!
On
ON/OFF
Turns output ON.