SP2060 Configuration Window
[Input A/B Link] Button
Although SP2060 configurations cannot be edited, the [Input A/B Link] status can be changed.
Clicking this button alternately turns INPUT A/B linking ON and OFF. When switched ON the input
level, EQ, and Delay component parameters are copied from Input A to Input B, and are thereafter
linked.
Probe Monitor
Probe monitor is a function that lets you monitor output ports in your configuration with headphones.
You can turn it ON or OFF using [Probe Monitor] in the [Tools] menu or the [Probe Monitor] button on
the toolbar. The probe monitor can be set to ON or OFF for each DME64N/24N.
The probe monitor can be used only when online with the DME64N/24N and Configuration window or
user module active. When the probe monitor is ON, no editing is possible except in the Component
Editor.
■
Probe Monitor Procedure
1
Turn the probe monitor ON.
Click [Probe Monitor] in the [Tools] menu or the [Probe Monitor] button on the toolbar.
The shape of the mouse pointer changes.
2
Click the output port you want to monitor.
The output port you clicked will be selected and monitoring will begin.
NOTE