85
Note: please refer to chapter 5-12-3 for hysteresis loop.
Optional trigger conditions:
Condition no.
Meaning
Unit
0
-
-
203
Current command
Rated current %
205
Current feedback
Rated current %
301
Speed command
rpm
302
Speed feedback
rpm
308
Speed deviation
rpm
4402
Position command
1 command
4404
Position feedback
1 command
1406
Position deviation
1 command
502
Bus voltage
V
503
Drive internal temperature
℃
506
Average output power
W
508
Average thermal power
W
condition
P5-16
When P5-14≥P5-15 or P5-14<P5-15, SOx output
Setting
value
Function
Default
setting
Suitable
mode
Change
Effecti
ve
0
P5-14≥P5-15, SOx output
0
All
the
modes
Servo
OFF
At
once
1
P5-14
<
P5-15, SOx output
2
P5-14 absolute value ≥P5-15, SOx
output
3
P5-14 absolute value
<
P5-15,
SOx output
P5-17
User-defined output 2 hysteresis loop
Unit
Default setting
Range
Suitable
mode
Change
Effecti
ve
Related to
trigger
condition
0
-32768~32767
All the modes
Servo
OFF
At
once
P5-53
Output terminal setting of user-defined output 2
Signal name
Default setting
Meaning
Change
User-defined
output 2
n.0000
Default setting
is
not
distribute to the
output terminal
Range 0000-0014, distribute to the
output terminal through P5-53
Содержание DS5E Series
Страница 1: ...DS5E DS5L series servo drive User manual WUXI XINJE ELECTRIC CO LTD Data No SC5 04 20190108 1 1 ...
Страница 2: ......
Страница 23: ...15 DS5E 45P5 PTA DS5E 47P5 PTA Unit mm 135 0 251 0 239 5 123 5 4 φ6 0 ...
Страница 105: ...97 2 select jog setting or manual setting to configure the inertia estimation trip 3 Set the auto tuning interface ...
Страница 117: ...109 4 Click ok to start the inertia identification 5 Configure the auto tuning parameters ...
Страница 173: ...165 ...