78
5.11 Absolute value system
5.11.1 absolute value system setting
In order to save the position data of absolute encoder, the battery unit needs to be installed.
Install the battery on the battery unit of the encoder cable with the battery unit.
If you do not use encoder cable with battery unit, please set P-79 to 1, that is, multi-loop absolute value
encoder is used as single-loop encoder.
Pararmeter
Name
setting
Meaning
Range
P0-79
Absolute
encoder battery
undervoltage
alarm switch
0
Normally use absolute encoder and use
battery to memorize position.
0~1
1(default)
Use
multi-loop
absolute
encoder
as
single-loop encoder and no longer remember
position (use absolute encoder as single-loop
encoder without battery)
5.11.2 Replace the battery
When replacing the battery, please replace the battery while keeping the driver and motor connected
well and the control power is connected. If the battery is replaced when the control power between the
driver and the motor is closed, the data stored in the encoder will be lost.
Note: Absolute Encoder Battery Model (This Battery Can't Charge)
CP-B-BATT
CPT-B-BATT (Special for Tank Chain)
Battery replacement steps
When using encoder cable with battery unit
(1) Only the control power of the servo unit is connected;
(2) Open the cover of the battery cell;
(3)
Take out the old battery, install the new one.
Содержание DS5E Series
Страница 1: ...DS5E DS5L series servo drive User manual WUXI XINJE ELECTRIC CO LTD Data No SC5 04 20190108 1 1 ...
Страница 2: ......
Страница 23: ...15 DS5E 45P5 PTA DS5E 47P5 PTA Unit mm 135 0 251 0 239 5 123 5 4 φ6 0 ...
Страница 105: ...97 2 select jog setting or manual setting to configure the inertia estimation trip 3 Set the auto tuning interface ...
Страница 117: ...109 4 Click ok to start the inertia identification 5 Configure the auto tuning parameters ...
Страница 173: ...165 ...