5.6.5 Speed command limit
Parameter
Meaning
Default
setting
Unit
Range
Change
Effective
P3-14
Forward max speed
command limit
4000
rpm
0
~
65535
Servo
OFF
At once
P3-15
Reverse max speed
command limit
4000
rpm
0
~
65535
Servo
OFF
At once
Note: P3-14 and P3-15 are effective in all the modes.
5.6.6 Zero clamp
(
/ZCLAMP
)
(1) Function
This function is used when host controller uses speed command input and the servo system isn’t
configured the position loop. In other words, the function will be used when the motor must stop and
enter lock state even the V-REF input voltage is not zero.
When set ON the zero clamp function, it will configure the position loop inside the servo, the motor
will do zero clamp within ±1 pulse at this position. The motor will return to zero clamp position even it
is run by external force.
The present speed must be smaller than zero clamp speed when using zero clamp function, it can clamp
the motor shaft from moving. The motor will switch from speed mode to position mode when starting
the zero clamp function. At this time, rotate the motor shaft, it will return to the original position. It will
not return to original position in speed mode, because it has no position feedback.
0
+SPEED1
Stop
+SPEED2
+SPEED3
-SPEED1
-SPEED2
-SPEED3
Speed 1
Speed 2
Speed 3
stop
Speed 1
Speed 2
Speed 3
Stop
Speed up down is decided by
P3-09, P3-10
SPD-A
SPD-B
SPD-D
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
Содержание DS5E Series
Страница 1: ...DS5E DS5L series servo drive User manual WUXI XINJE ELECTRIC CO LTD Data No SC5 04 20190108 1 1 ...
Страница 2: ......
Страница 23: ...15 DS5E 45P5 PTA DS5E 47P5 PTA Unit mm 135 0 251 0 239 5 123 5 4 φ6 0 ...
Страница 105: ...97 2 select jog setting or manual setting to configure the inertia estimation trip 3 Set the auto tuning interface ...
Страница 117: ...109 4 Click ok to start the inertia identification 5 Configure the auto tuning parameters ...
Страница 173: ...165 ...