119
Mechanical resonance
frequency
mechanical system
Amplitude frequency
characteristic
Notch
characteristics
Notch
width
Notch
depth
frequency
frequency
Principle diagram of notch filter
The servo driver has five sets of notch filters, each with three parameters, notch frequency, notch
attenuation and notch bandwidth. The first and second notches are set automatically, and the third,
fourth and fifth are set manually.
The torque instruction filter and notch filter are in series in the system. As shown in the figure below,
the switch of the notch filter is controlled by P2-69 and P2-70.
Torque
command
filter
P2-35
First
notch
filter
P2-71
P2-72
P2-73
Second
notch
filter
P2-74
P2-75
P2-76
Third
notch
filter
P2-77
P2-78
P2-79
Fourth
notch
filter
P2-80
P2-81
P2-82
Fifth
notch
filter
P2-83
P2-84
P2-85
Torque
instruction
after filter
Torque
instruction
before
filter
P2-69
control
P2-70
control
Parameter
Meaning
Default
setting
Change
Effective
P2-69
n.□□□0
First notch off
n.□□□0
Anytime
At once
n.□□□1
First notch on
n.□□0□
Second notch off
n.□□0□
Anytime
At once
n.□□1□
Second notch on
n.0□□□
Third notch off
n.0□□□
Anytime
At once
n.1□□□
Third notch on
P2-70
n.□□□0
Fourth notch off
n.□□□0
Anytime
At once
n.□□□1
Fourth notch on
n.□□0□
Fifth notch off
n.□□0□
Anytime
At once
n.□□1□
Fifth notch on
Содержание DS5E Series
Страница 1: ...DS5E DS5L series servo drive User manual WUXI XINJE ELECTRIC CO LTD Data No SC5 04 20190108 1 1 ...
Страница 2: ......
Страница 23: ...15 DS5E 45P5 PTA DS5E 47P5 PTA Unit mm 135 0 251 0 239 5 123 5 4 φ6 0 ...
Страница 105: ...97 2 select jog setting or manual setting to configure the inertia estimation trip 3 Set the auto tuning interface ...
Страница 117: ...109 4 Click ok to start the inertia identification 5 Configure the auto tuning parameters ...
Страница 173: ...165 ...