52
1
After
the
instruction
is
finished,
the
deviation is below
P5-00 and COIN
signal is output.
|
U0-08
|
Pulse offset
P5-00
ON
/S-ON
Signal status
/COIN
Signal status
ON
ON
OFF
|
ΔU0-12
|
Pulse command
2
When
the
instruction
ends
and
the
motor
speed is under the
rotation detection
speed (P5-03) and
the
absolute
deviation is less
than P5-00,
the
COIN
signal
is
output.
|
U0-08
|
Pulse offset
P5-00
ON
/S-ON
Signal status
/COIN
Signal status
ON
ON
OFF
|
ΔU0-12
|
Pulse command
|
U0-00
|
Actual speed
P5-03
3
At the end of
instruction,
the
absolute deviation
value under P5-00,
it outputs COIN
signal. If COIN
maintains
P5-02
time, COIN-HOLD
signal is output.
|
U0-08
|
Pulse offset
P5-00
ON
/S-ON
Signal status
/COIN
Signal status
ON
ON
OFF
|
ΔU0-12
|
Pulse command
/COIN-HOLD
Signal status
ON
OFF
P5-02
P5-02
5.3.7 Positioning near signal
(
/NEAR
)
Parameter Signal name
Setting
Meaning
Range
P5-46
Positioning
near /NEAR
n.0000
(default)
Default
unallocated
output
terminal
The range of parameters
is 0001-0014.
can be assigned to other
output terminals through
P5-46.
n.0002
Output signal from SO2 terminal
Содержание DS5E Series
Страница 1: ...DS5E DS5L series servo drive User manual WUXI XINJE ELECTRIC CO LTD Data No SC5 04 20190108 1 1 ...
Страница 2: ......
Страница 23: ...15 DS5E 45P5 PTA DS5E 47P5 PTA Unit mm 135 0 251 0 239 5 123 5 4 φ6 0 ...
Страница 105: ...97 2 select jog setting or manual setting to configure the inertia estimation trip 3 Set the auto tuning interface ...
Страница 117: ...109 4 Click ok to start the inertia identification 5 Configure the auto tuning parameters ...