32
U0-22 input signal 2 distribution
Segment
code
Description
Segment
code
Description
11
/C-SEL control mode selection
12
/ZCLAMP zero clamp
13
/INHIBIT
instruction
pulse
prohibition
14
/G-SEL gain switch
15
/CLR pulse clear
16
/CHGSTP change step
17
Reserved
18
Reserved
19
Reserved
20
Reserved
Note: When reading through communication, the binary numbers read from right to left correspond to
the position of / C-SEL, / ZCLAMP, 0 means that the position signal is not input, 1 means that the
position signal has input. Example: 0x0001 means / C-SEL has input, 0x0041 means / C-SEL and /
G-SEL have input.
U0-23 output signal status
STA/ESC
INC
DEC
ENTER
1
2
3
4
5
6
7
8
9
10
Lighting means that the corresponding
item has signal output
Lighting means that the corresponding
item has no signal output
U0-23 output signal 1 distribution
Segment
code
Description
Segment
code
Description
1
Positioning
completion
hold
(
/COIN_HD
)
2
Positioning completion
(
/COIN
)
3
Same speed detection
(
/V-CMP
)
4
Rotate detection
(
/TGON
)
5
Ready
(
/S-RDY
)
6
Torque limit
(
/CLT
)
7
Speed limit detection
(
/VLT
)
8
Break lock
(
/BK
)
9
Warn
(
/WARN
)
10
Output near
(
/NEAR
)
Note: When reading through communication, the binary numbers read from right to left correspond to
the position of / COIN_HD, / COIN, 0 means that the position signal is not output, 1 means that the
position signal has output. Example: 0x0001 means / COIN_HD has output, 0x0201 means /
COIN_HD and / NEAR has output.
Содержание DS5E Series
Страница 1: ...DS5E DS5L series servo drive User manual WUXI XINJE ELECTRIC CO LTD Data No SC5 04 20190108 1 1 ...
Страница 2: ......
Страница 23: ...15 DS5E 45P5 PTA DS5E 47P5 PTA Unit mm 135 0 251 0 239 5 123 5 4 φ6 0 ...
Страница 105: ...97 2 select jog setting or manual setting to configure the inertia estimation trip 3 Set the auto tuning interface ...
Страница 117: ...109 4 Click ok to start the inertia identification 5 Configure the auto tuning parameters ...
Страница 173: ...165 ...