96
instruction
speed
will
lead
to
inaccurate
identification of inertia ratio.
③
torque limit too small
(
P3-28/29
)
Err-2
value error is too
large
when
calculating
the
inertia
①
The maximum speed limit is too small (P2-17),
but it is recommended not to be less than 500 rpm.
Low instruction speed will lead to inaccurate
identification of inertia ratio.
②
The presumed inertia trip is too small. It is
suggested that the minimum for P2-15 should no be
less than 50 (0.5 cycles). If the trip is too small, the
identification of inertia ratio will be inaccurate.
③
mechanism friction too large
④
overshoot
The
maximum
speed limit is too
small; the travel
is too small; the
friction of the
mechanism is too
large; the overrun
occurs
Err-3
Driver
internal
trip
calculation
error
①
The presumed inertia trip is too small. It is
suggested that the minimum for P2-15 should no be
less than 50 (0.5 cycles). If the trip is too small, the
identification of inertia ratio will be inaccurate.
Contact us
Err-5
Unrestrained
Vibration in the
Process of Inertia
Identification
Unhandled vibration occurs
Unhandled
vibration occurs
Err-6
Driver
is
not
currently in BB
state
①
Enable have been opened. P5-20 can be set to 0
first
②
When the driver alarms, it will appear. Press
ESC key to exit the auto-tuning interface to see if
there is an alarm.
Will occur when
enable is turned
on or driver has
alarm
Err-7
The driver alarms
in the process of
inertia
identification
Driver has alarm, press ESC key to exit the
auto-tuning interface, check the alarm code, first
solve the alarm and then make inertia estimation.
Driver has alarm
Estimate the inertia through XinJeServo software
1.
Click auto-tuning on the main interface of XinJeServo
Содержание DS5E Series
Страница 1: ...DS5E DS5L series servo drive User manual WUXI XINJE ELECTRIC CO LTD Data No SC5 04 20190108 1 1 ...
Страница 2: ......
Страница 23: ...15 DS5E 45P5 PTA DS5E 47P5 PTA Unit mm 135 0 251 0 239 5 123 5 4 φ6 0 ...
Страница 105: ...97 2 select jog setting or manual setting to configure the inertia estimation trip 3 Set the auto tuning interface ...
Страница 117: ...109 4 Click ok to start the inertia identification 5 Configure the auto tuning parameters ...
Страница 173: ...165 ...