43
2. BK signal
Parameter
Signal
name
setting
Meaning
Range
P5-44
Brake lock
/BK
n.0000
(default)
Default
unallocated
output
terminal
The range of parameters
is 0001-0014.
can be assigned to other
output terminals through
P5-44.
n.0001
Use SO1 terminal output signal to
control brake
3. Switching time of BK signal and S-ON signal
Because of the action delay time of brake, the machine moves slightly under the action of gravity and
so on. P5-07 parameter is used to adjust the time. Delay this time to release the brake after enabling or
lock the brake and delay this time when the enable signal is off.
Parameter
Meaning
Default
setting
Unit
Range
Change
Effective
P5-07
Servo OFF delay
time
500
1ms
0
~
65535
Servo
OFF
At once
Note: The setting here is the time when the rotation detection TGON is invalid when the motor is
stopped.
When setting the servo motor with brake, the output signal of the control brake "/BK" and the time of
ON/OFF action of the servo SON signal are shown below. That is, before the output /BK signal lock-in
is opened, the servo motor has entered the power-on enabling state; after not output /BK signal and
brake is locked, the servo motor is disconnected from the power-on state.
Servo OFF before
P5-07 brake locked
/S-ON input
/BK output
4. Setting of brake closing parameters
Parameter
Meaning
Default
setting
Unit
Range
Change
Effective
P5-08
Brake command
output speed
30
rpm
20
~
10000
Servo
OFF
At once
P5-09
Brake command
wait time
500
ms
0
~
65535
Servo
OFF
At once
When the alarm occurs, the motor quickly becomes non-electrified. Because of gravity or inertia
and other reasons before the brake action time, the machine will move. To avoid this situation, the
above parameters need to be set.
The sequence diagram is as follows:
Содержание DS5E Series
Страница 1: ...DS5E DS5L series servo drive User manual WUXI XINJE ELECTRIC CO LTD Data No SC5 04 20190108 1 1 ...
Страница 2: ......
Страница 23: ...15 DS5E 45P5 PTA DS5E 47P5 PTA Unit mm 135 0 251 0 239 5 123 5 4 φ6 0 ...
Страница 105: ...97 2 select jog setting or manual setting to configure the inertia estimation trip 3 Set the auto tuning interface ...
Страница 117: ...109 4 Click ok to start the inertia identification 5 Configure the auto tuning parameters ...
Страница 173: ...165 ...