29
small category under the category.
4.2 Running Display Status Description
Speed torque control mode
Speed
consistency V-
CMP
Torque limit CLT
Rotate detection
TGON
Speed limit VLT
Zero clamp
ZCLAMP
1.
Digit display contents
Digit data
Display contents
P5-39
Same
speed
detection
(
/V-CMP
)
When the actual speed of the motor is the same as the command speed,
turn on the light.
Detection Width of Same Speed Signal: P5-04 (Unit: rpm)
P5-42
Torque limit
(
/CLT
)
When the speed is controlled, when the torque exceeds the set value,
turn on the light.
Internal Forward Torque Limitation: P3-28
Internal Reverse Torque Limitation of: P3-29
P5-40
Rotate detection
(
/TGON
)
P5-03
(单位:
rpm
)
When the motor speed is higher than the rotating
speed, turn on the lamp.
Rotation detection speed: P5-03 (unit: rpm)
P5-31
Zero clamp
(
/ZCLAMP
)
When the zero clamp signal starts to operate, turn on the light.
P5-43
Speed limit
(
/VLT
)
When the speed exceeds the set value, turn on the light when the torque
is controlled.
Forward speed limit in torque control: P3-16; reverse speed limit: P3-17.
2.
Short code display content
Short code
Display contents
Standby status
Servo OFF status. (The motor is in a non-electrified state)
In operation
Servo enabling state. (The motor is on-line)
Need reset status
Servo needs to be re-energized
Forbidden forward drive state
P-OT ON status. Refer to Section 5.2.4, "Overrun Prevention".
Forbidden reversal drive state
N-OT ON status. Refer to Section 5.2.4, "Overrun Prevention".
Содержание DS5E Series
Страница 1: ...DS5E DS5L series servo drive User manual WUXI XINJE ELECTRIC CO LTD Data No SC5 04 20190108 1 1 ...
Страница 2: ......
Страница 23: ...15 DS5E 45P5 PTA DS5E 47P5 PTA Unit mm 135 0 251 0 239 5 123 5 4 φ6 0 ...
Страница 105: ...97 2 select jog setting or manual setting to configure the inertia estimation trip 3 Set the auto tuning interface ...
Страница 117: ...109 4 Click ok to start the inertia identification 5 Configure the auto tuning parameters ...
Страница 173: ...165 ...