117
2.
Press ENTER, panel shows Son and flashes, turn on the enabler by manual;
3.
After turn on the enabler, panel shows tune and flickers, enter auto-tuning process;
4.
The upper device starts to send pulses, then it will show done and flicker
5.
Press STA/ESC to exit
6.
Vibration suppression parameters are automatically written into the second and first notches
(the second notches are preferred when there is only one vibration point). The related
parameters are detailed in 6.7.6 notch filter.
Fault alarm of panel in vibration suppression process
Error code
Meaning
Reasons
Err-1
Failure to search for optimal gain
Too large inertia ratio; too weak rigidity of
mechanism
Err-2
(1) Overrun/alarm occurs during
auto-tuning
(2)
External
instruction
auto-tuning/Vibration Suppression
Mode: Servo turns off the Enabler
in auto-tuning process
Please make sure that there is no overrun and
alarm before auto-tuning.
Make sure that the enabler is not turned off when
auto-tuning
Err-3
Non-position control mode
please auto-tune in position mode
Err-4
Not turn off the adaptive function
please set P2-01.0 to 0, then auto-tune
Err-7
Driver
alarm
in
auto-tuning
process
driver alarmed
Err-8
Positioning Completion Signal
Instability
Short instruction interval
6.7.4 Vibration suppression (PC software)
1. open XinJeServo software, click mechanical properties;
2. click measure;
3. set the measure conditions, then click execute;
4. select amplitude and phase;
Содержание DS5E Series
Страница 1: ...DS5E DS5L series servo drive User manual WUXI XINJE ELECTRIC CO LTD Data No SC5 04 20190108 1 1 ...
Страница 2: ......
Страница 23: ...15 DS5E 45P5 PTA DS5E 47P5 PTA Unit mm 135 0 251 0 239 5 123 5 4 φ6 0 ...
Страница 105: ...97 2 select jog setting or manual setting to configure the inertia estimation trip 3 Set the auto tuning interface ...
Страница 117: ...109 4 Click ok to start the inertia identification 5 Configure the auto tuning parameters ...
Страница 173: ...165 ...