151
U2-24
Firmware generation date: hour/minute
Appendix 3. FX-XX auxiliary function parameters
Code
Contents
Effective
Refrence chapter
F0-00
Clear the alarm
Servo OFF
F0-01
Restore to out of factory settings
Servo OFF
F0-02
clear the position offset
Servo OFF
F1-00
Jog run
Servo OFF
F1-01
Test run
Servo OFF
F1-02
Current Sampling Zero-correction
Servo OFF
F1-03
Vref (speed analog) zero-correction
Servo OFF
F1-04
Tref (torque analog) zero-correction
Servo OFF
F1-05
software enable
Servo OFF
F1-06
Clear multi-loop data, clear alarm
Servo OFF
Appendix 4. Modbus address list
Parameter
Modbus address
Notes
P0-00~P0-xx
0x0000~0x0021
Modbus address is added 1 in turn from 0x0000, for
example, Modbus address of P0-23 is 0x0017
P1-00~P1-xx
0x0100~0x011C
Modbus address is added 1 in turn from 0x0100, for
example, Modbus address of P1-10 is 0x010A
P2-15~P2-xx
0x020F~0x0224
Modbus address is added 1 in turn from 0x020F, for
example, Modbus address of P2-16 is 0x0210
P3-00~P3-xx
0x0300~0x0324
Modbus address is added 1 in turn from 0x0300, for
example, Modbus address of P3-13 is 0x030D
P4-00~P4-xx
0x0400~0x041F
Modbus address is added 1 in turn from 0x0400, for
example, Modbus address of P4-25 is 0x0419
P5-00~P5-xx
0x0500~0x0535
Modbus address is added 1 in turn from 0x0500, for
example, Modbus address of P5-20 is 0x0514
P6-00~P6-xx
0x0600~0x06xx
Modbus address is added 1 in turn from 0x0600, for
example, Modbus address of P6-05 is 0x0605
P7-00~P7-xx
0x0700~0x070F
Modbus address is added 1 in turn from 0x0700, for
example, Modbus address of P7-11 is 0x070B
U0-00~U0-xx
0x1000~0x1035
Modbus address is added 1 in turn from 0x1000, for
example, Modbus address of U0-05 is 0x1005
U1-00~U1-xx
0x1100~0x1119
Modbus address is added 1 in turn from 0x1100, for
example, Modbus address of U1-14 is 0x110E
U2-00~U2-xx
0x1200~0x1214
Modbus address is added 1 in turn from 0x1200, for
example, Modbus address of U2-08 is 0x1208
F0-00~F0-xx
0x2000~0x2002
Modbus address is added 1 in turn from 0x2000, for
example, Modbus address of F0-01 is 0x2001
F1-00~F1-xx
0x2100~0x2105
Modbus address is added 1 in turn from 0x2100, for
example, Modbus address of F1-03 is 0x2103
Содержание DS5E Series
Страница 1: ...DS5E DS5L series servo drive User manual WUXI XINJE ELECTRIC CO LTD Data No SC5 04 20190108 1 1 ...
Страница 2: ......
Страница 23: ...15 DS5E 45P5 PTA DS5E 47P5 PTA Unit mm 135 0 251 0 239 5 123 5 4 φ6 0 ...
Страница 105: ...97 2 select jog setting or manual setting to configure the inertia estimation trip 3 Set the auto tuning interface ...
Страница 117: ...109 4 Click ok to start the inertia identification 5 Configure the auto tuning parameters ...
Страница 173: ...165 ...