6.
Define the Data Filter Format:
The prompt at the bottom
of the menu is used to define the Data Filter.
a) Press the dash key to indicate a field position that you
do not
need to monitor. The last line in Figure 7.3
shows a Data Filter Format where dashes have been
entered in the first four fields of the call record.
b) When you reach a field you want to monitor, type a
series of variables (any uppercase letter from A to Z) to
assign a variable to that position. For example, to
assign the variable "A" to represent the first seven digits
of the number dialed, enter seven A's (
AAAAAAA
). The
same variable is repeated for each position in the field.
It is not necessary to define variables in alphabetic
order.
c) When you reach the end of the call record, or the last
position you need to monitor, press
[Enter]
. The Data
Filter Format will be saved, and NetLink will return to
the Data Filter Configuration menu.
7-5
The Data Filters
DEFINE FORMAT:
In order to assist the user during format definition, several data records
and the previous format are displayed in the following order:
Data Records
(If available)
Previous Format
(If available)
Enter new format at cursor.
<Space><Enter> to clear.
Use upper case letters for fields,
'-' between fields
|08:16|075|B.JOHNSON
|IN |
|00:55|00.00|
|08:18|067|R.JONES
|OUT|19495839514
|05:36|00.75|
|08:20|092|J.SMITH
|OUT|18008547226
|11:15|00.00|
(undefined)
---------+---------+---------+---------+---------+---------+---------+---------
----------------------------------AAAAAAA
Figure 7.3: Data Filter Format Definition Example