12.1. Alarm Actions for Alarm Filter Clues
NetLink allows the definition of up to sixteen Alarm Clues for
each of the two Alarm Filters. Each clue can be assigned its own
individual Alarm Action. For example, when one Alarm Clue is
triggered, the unit may perform a callout, when another Clue is
triggered, the unit may perform an Output Contact operation.
In addition, each clue can be assigned separate callout numbers or
pager numbers. When Alphanumeric Page is selected, up to three
different Pager ID Numbers can be assigned to each clue. This
allows the NetLink to direct calls to a specific employee,
depending on the nature of the alarm.
When Alarm Filters are configured, NetLink provides the option of
defining default Alarm Actions that can be applied to all newly
defined clues. In cases where an identical action will be applied to
a series of clues, this allows you to enter action parameters for all
clues without manually entering specifications for each clue. Note
that these default parameters are not applied to the PBX Inactivity
Alarms, 80% Full Alarm, or Output Contact Alarms.
12.2. Alarm Action Summary
12.2.1. None (No Alarm Action)
When this Alarm Action is selected, NetLink will
not
perform a
special task when an alarm is generated. Note however, that call
records will still be counted and flagged according to the clue
matched. When data is released to the polling device, call records
can still be sorted by the Alarm Clue matched.
12-2
PollCat NetLink User's Guide