B92
Define PBX Port A Communication
Parameters
(Supervisor Mode Only)
Defines the baud rate, parity, data bits,
and stop bits for PBX Port A. This command uses the following
format:
^B92,baud,parity,data,stop
[Enter]
Where:
baud
Baud Rate:
Any standard rate from 300 bps to 115.2
Kbps. Note that it is only necessary to enter the first two
characters of the baud rate. If an asterisk is entered in this
field, the port will be set to the default rate specified by
Set-Up switches 4 and 5.
parity
Parity Bits:
None (
n
), Odd (
o
), or Even (
e
)
data
Data Bits:
7
or
8
stop
Stop Bits:
1
or
2
Corresponding Menu Function:
PBX Port A Configuration
Menu.
^
B93
Define PBX Port B Communication
Parameters
(Supervisor Mode Only)
Defines the baud rate, parity, data bits,
and stop bits for PBX Port B. This command uses the following
format:
^B93,baud,parity,data,stop
[Enter]
Where:
baud
Baud Rate:
Any standard rate from 300 bps to 115.2
Kbps. Note that it is only necessary to enter the first two
characters of the baud rate. If an asterisk is entered in this
field, the port will be set to the default rate specified by
Set-Up switches 4 and 5.
parity
Parity Bits:
None (
n
), Odd (
o
), or Even (
e
)
data
Data Bits:
7
or
8
stop
Stop Bits:
1
or
2
Corresponding Menu Function:
PBX Port B Configuration
Menu.
18-29
Command Reference Guide
Содержание PollCat NetLink
Страница 2: ......
Страница 20: ...3 8 PollCat NetLink User s Guide...
Страница 74: ...6 24 PollCat NetLink User s Guide...
Страница 140: ...14 6 PollCat NetLink User s Guide...
Страница 255: ......
Страница 256: ...5 Sterling Irvine California 92618 949 586 9950 Toll Free 1 800 854 7226 Fax 949 583 9514 http www wti com...