Action Parameters:
The Action Delay is the amount of time
that will elapse between alarm actions sent from this port.
·
Output Parameters:
§
Output Mode:
The format used when data is released via
this port; ASCII Record, Binary Block, Xmodem, or
ZModem.
§
Data on ^B01:
When disabled, a ^B02 command is
required in order to begin data release.
§
Hold End Data:
When enabled, a ^B02 command is
required in order to release the "End Data" message.
§
Line # Tag:
When enabled, a line number will be inserted
at the beginning of each record released by this port.
§
Send Compressed:
When enabled, this port will release
data in space compressed format.
§
Auto Delete:
When enabled, stored data will be erased
after the polling device acknowledges reception.
·
Output Parameters (Binary Block):
Lists parameters used
when this port releases data in Binary Block format:
§
Transmit Attempts:
The number of transmit attempts, and
the length of the delay between attempts.
§
DLE Stuffing:
When enabled, literal characters can be
inserted into binary data released via this port.
·
Callout Parameters:
§
Dial Attempts:
The number of times NetLink will attempt
to place an outgoing call.
§
Sequence Attempts:
The number of times NetLink will
restart the dial-out process, and the delay between each
sequence of dial-out attempts.
§
Immediate Callout:
When enabled, NetLink will dial the
defined Callout Number immediately after the user
disconnects from the Modem Port.
§
Immediate Phone #:
The number dialed when an
Immediate Callout is performed.
§
Dialback Security:
The status of the Dialback Security
feature. For more information, please refer to
Section 4.4.4.1.
6-20
PollCat NetLink User's Guide
Содержание PollCat NetLink
Страница 2: ......
Страница 20: ...3 8 PollCat NetLink User s Guide...
Страница 74: ...6 24 PollCat NetLink User s Guide...
Страница 140: ...14 6 PollCat NetLink User s Guide...
Страница 255: ......
Страница 256: ...5 Sterling Irvine California 92618 949 586 9950 Toll Free 1 800 854 7226 Fax 949 583 9514 http www wti com...