8.8.
Assigning the Alarm Filter to a Port
After defining the Alarm Filter, the next step is to assign the filter
to one or more input ports. The Port Configuration menus are used
to assign one of the available Alarm Filters to each port as
described in Section 4.4. Note that Alarm Filters will not function
until they are assigned to a port.
8.9.
Match Parameter Definition Examples
The following examples are based on fictional PBX call record
formats. When designing your Alarm Filter, be aware that the
record structure will differ from those shown in the examples.
When defining the Alarm Filter Format and Match Parameters the
following factors must be considered:
·
Exact Match:
Alphanumeric values in parameter definitions
must
exactly
match those found in the call record. If the
record shows the time as "09:00", then the match parameters
must also list the time as "09:00", and not "0900" or "9:00".
·
Number of Characters :
For any given variable, the number
of characters specified in the Alarm Filter Format must
exactly
match the number of characters indicated in the Match
Parameters definition. For example, if the filter format
defines the variable “B” as the first seven characters of the
number dialed, then the parameter definition must account for
all seven characters.
·
Searching for Operator Characters:
When searching for a
text string which contains a space character or any character
that is also one of NetLink's logical operators (e.g.
>
,
<
, or
&
)
a backslash (
\
) must precede the space or operator. For
example, to search for "
***Error***
", the match parameter
would be defined as "
\*\*\*Error\*\*\*
". Likewise,
when searching for "
hello there
", the match parameter
would be defined as "
hello\ there
".
·
Variable Case:
When defining and using variables, take care
to use the correct case. Real Time variables are always
entered as lowercase characters; regular variables are always
entered as uppercase characters.
8-18
PollCat NetLink User's Guide
Содержание PollCat NetLink
Страница 2: ......
Страница 20: ...3 8 PollCat NetLink User s Guide...
Страница 74: ...6 24 PollCat NetLink User s Guide...
Страница 140: ...14 6 PollCat NetLink User s Guide...
Страница 255: ......
Страница 256: ...5 Sterling Irvine California 92618 949 586 9950 Toll Free 1 800 854 7226 Fax 949 583 9514 http www wti com...