t
Time:
Tells NetLink to determine the time each record is
received. The time is entered in "HH:MM" format, where
HH is the hour (00 - 23), and MM is the minute (00 - 59).
w
Day of the Week:
Tells NetLink to determine the day of
the week when the record is received. The day of the week
is entered as a single digit, where 1 = Sunday, 2 = Monday,
3 = Tuesday, 4 = Wednesday, 5 = Thursday, 6 = Friday, and
7 = Saturday.
d
Date:
Tells NetLink to determine the date the record is
received. The date is entered in "MM/DD" format, where
MM is the month (01 - 12) and DD is the date (01 - 31).
Example 1:
To create an Alarm Filter Clue that will count call
records received on Sunday, match parameters would be defined as
w=1
. Where
w
is the Real-Time variable for the day of the week,
and
1
indicates Sunday.
Example 2:
To create an Alarm Filter Clue that will count call
records received after 6:00 pm (18:00) or before 7:00 am (07:00),
match parameters would be defined as follows:
t>18:00+t<07:00
Where
t
is the Real-Time variable for the time of day, and
+
is the
logical OR operator.
Notes:
·
Real-Time variables are
not
defined in the Alarm
Filter Format.
·
The match parameter definition can include both
Real-Time variables and regular variables, as well
as logical and relational operators.
·
Real-Time variables function independently from
the Time/Date Stamp. The Time/Date Stamp does
not have to be enabled in order for the Real-Time
variables to function.
·
Values from the internal clock/calendar are not
included in the call record, unless the Time/Date
Stamp is enabled.
8-17
The Alarm Filters (Toll Fraud Detection)