16.1.4. Clear Alarm Condition
The "Clear Alarm Condition" function is used to cancel pending
Alarm Actions. Note that this function will
not
clear Alarm
Counters; therefore, additional records that match a counter which
has passed the threshold
will
generate additional Alarm Actions.
Example:
Assume that the counter for an Alarm Clue named
"TEST" has exceeded its threshold and has generated five pending
Alarm Actions. If the Clear Alarm Condition function is invoked,
pending actions will be canceled, but the counter for TEST will
not be reset. Any additional call records that match the TEST
Clue will generate additional Alarm Actions.
To activate the Clear Alarm Condition function from the Main
Menu, type
3
and press
[Enter]
to access the System Functions
menu. From the System Functions Menu, type
4
and press
[Enter]
. All pending Alarm Actions will be canceled.
16.1.5. Clear Alarm Counters
This function is used to reset Alarm Clue Counters to zero:
1. From the Main Menu, type
3
and press
[Enter]
to access
the System Functions Menu. From the System Functions
Menu, type
5
and press
[Enter]
.
2. NetLink will prompt the user to select Alarm Filter 1 or 2.
Key in the number for the desired filter and press
[Enter]
.
3. NetLink will list all clues for the selected Alarm Filter.
a) To reset the counter for a specific Alarm Clue, key in
the name of the desired clue and press
[Enter]
.
b) To reset counters for all clues for the selected Alarm
Filter, type
*
(asterisk) and press
[Enter]
.
c) To exit from the clue selector screen and return to the
Alarm Filter selector screen, press
[Esc]
.
16-4
PollCat NetLink User's Guide