10. The 80% Full Alarm
The 80% Full Alarm is designed to notify the user when internal
memory becomes approximately 80% Full. NetLink can send an
SNMP Trap, call a modem or pager, or contact the user via the
Console Port. This Alarm can also execute a user-defined
command string or open/close the optional Output Contacts.
To configure the alarm, go to the Main Menu. Type
25
and press
[Enter]
to access the Alarm Configuration menu. When the menu
appears, type
5
and press
[Enter]
. The 80% Full Alarm
Configuration Menu (Figure 10.1) offers the following options:
1.
80% Full Alarm:
Enables/disables the 80% Full Alarm. In
order to function, the alarm must be enabled.
2.
Action:
Determines how NetLink will react when an 80%
Full Alarm is generated. The options are None, Callout,
Alphanumeric Page, Numeric Page, SNMP Trap, Output
Contact, or Console action. For more information, please
refer to Section 12.
3.
Phone Number:
The number dialed for a callout or page.
Note:
For Numeric Paging, this prompt can specify
both a phone number and numeric "message". In this
case, the number is entered as follows:
PHONENO@MESSAGENO#
Where "
PHONENO
" is the pager number, and
"
MESSAGENO
" is any number that notifies the user
that an alarm has occurred. For example, to dial
555-1212 and send the message "999", item 3 would
be defined as "
5551212@999#
".
4.
Pager ID 1:
The first Pager ID Number dialed for an
Alphanumeric Page action. NetLink can dial up to three
pagers for this alarm.
5. The second Pager ID Number for the 80% Full Alarm.
6. The third Pager ID Number for the 80% Full Alarm.