3.3.
Reset to Defaults
This procedure will reset the NetLink to the settings indicated by
the Set-Up switches, reset all menu selected parameters to factory
defaults, and clear the flash memory.
When the unit is shipped from the factory, defaults are reset and
the memory is cleared. However, if the NetLink has been
previously installed, or if you have changed switch settings, this
procedure should be performed. It is also recommended to reset
the unit after installing additional memory modules.
Notes:
·
When this procedure is performed, all menu
defined parameters will be cleared. If the unit has
already been configured, parameter settings should
be saved (as described in Section 14.2), before
beginning this procedure.
·
If the NetLink unit has the base 512K memory
option (no SIMMs), all stored data will be cleared.
If the unit has collected data, it is recommended to
retrieve stored data (as described in Section 15)
before beginning this procedure.
To reset defaults and clear memory, proceed as follows:
1. Press the NetLink Main Power Switch to the OFF position.
2. Press and hold the Reset Button (located on the back panel)
while pressing the Main Power Switch to the ON position.
Continue to hold the Reset Button until the front panel
indicators blink twice.
3. After the indicators blink, release the Reset Button. After a
brief pause, the front panel indicators will blink three times.
This indicates that the reset procedure is complete.
3-5
Hardware Installation
Содержание PollCat NetLink
Страница 2: ......
Страница 20: ...3 8 PollCat NetLink User s Guide...
Страница 74: ...6 24 PollCat NetLink User s Guide...
Страница 140: ...14 6 PollCat NetLink User s Guide...
Страница 255: ......
Страница 256: ...5 Sterling Irvine California 92618 949 586 9950 Toll Free 1 800 854 7226 Fax 949 583 9514 http www wti com...