Actions to take:
Check the loom connects to all parts and no wires are not connected.
Check machine settings and recipes to ensure only used components are enabled
Check the supply fuses
Check if any outputs switch on when the machine is powered-up. If so, replace the processor board. If
no outputs switch on, this will indicate a faulty component driven from SKT J13, J14 or J15.
Error code 15
Fault Description
– Waste bucket faulty
Actions to take:
Check the waste bucket is not full. Empty if full of water
Ensure the waste bucket brass weight is on the waste bucket
Ensure the waste buck is in the correct position
Ensure that the waste bucket white silicon hose is not trapped or twisted.
Check the waste bucket switch for damage
Error code 17
Fault Description
– Triac open circuit
Actions to take:
Triac on control board has gone open circuit
Ensure connections on the control board are correctly connected
Check the fault log for a fault prior to this error which may have caused the fault.
Check the output is not shorted at the motor / valve end
Return board for fault diagnostic
Error code 19
Fault Description
– Keyboard Fault.
Actions to take:
Ensure that the hover buttons are not touched during power up
Disconnect each non touch button in turn and power up the machine to locate a faulty button. If the
fault disappears then check the button / loom and replace as required.
If fault persists then replace the processor board.
Error code 20
Fault Description
– Water Fail safe
Actions to take:
Water fail safe is caused by the operation of the main water inlet valves outside of a vend cycle for a pre-set
time limit. Water fail safe is not the same a water leak detection device where a water block should be installed
to prevent water leaks.
Check the machine for internal water leaks
Fault code will be rectified by interrupting power.
Error code 23
Fault Description
– Blown Fuse Detected.
Actions to take:
Check and / or replace Fuse 1 (1.2A) and/or Fuse 2 (6.3A) on processor board.
Check that triacs being used have an output.
Check the motor and loom for short circuits
Error code 40
Fault Description
– Internal Timer
Actions to take:
If the number of software timers exceeds 64. Internal software memory fault condition
Check fault log and report error to Westomatic vending services.
Cycle power to restart machine.
No further action required unless fault re occurs multiple times.
Error code 71
Fault Description
– Juice 1 sold out
Actions to take:
Replace juice 1
Reset the syrup counter in door open mode menu