Use buttons
1
or
2
to scroll to the output number setting.
Press
3L
to enter and change the output number.
The LCD will flash the output setting 00. ( Maximum setting 200 )
Use buttons
1
or
2
to change the output number.
Press
3L
to save the output setting.
Press cancel
3S
to exit back into ‘Door Open Mode’ to save settings to the VMC.
Note:
Any changes to output number must be done with due care. Drink makeup and abnormal
machine functions may occur if selecting an incorrect output number.
13.6.4
►FLAVOUR SHOT
The main water for the recipe refers to the throw times to fill a bottle with a juice shot.
└―――――►
Drink Throws
└―――――►
Flavour shot
└―――――►
Cup not used
← Cup setting not used
└―――――►
Cup not used
← Cup setting not used
└―――――►
Bottle fill
← Juice throw to fill a bottle
└―――――►
Delay
← Delay before the Juice starts
└―――――►
Pulse On
← Syrup pulse on time
└―――――►
Pulse Off
← Syrup pulse off time
└―――――►
Output number
← Syrup output circuit number
13.6.4.1
Bottle fill
This setting defines the time the flavour pump runs.
Use buttons
1
or
2
to scroll to the Bottle fill setting.
Press
3L
to enter and change the throw time.
The LCD will flash the time setting 00.0. ( Maximum time 60.0s )
Use buttons
1
or
2
to change the time.
Press
3L
to save the time setting.
Press cancel
3S
to exit back into ‘Door Open Mode’ to save settings to the VMC.
13.6.4.2
Delay
This setting defines the start delay time of the juice pump.
Use buttons
1
or
2
to scroll to the delay setting.
Press
3L
to enter and change the start delay time.
The LCD will flash the time setting 00.0. ( Maximum time 60.0s )
Use buttons
1
or
2
to change the time.
Press
3L
to save the time setting.
Press cancel
3S
to exit back into ‘Door Open Mode’ to save settings to the VMC.
13.6.4.3
Pulse ON / OFF
This setting defines the on and off duration for the juice. Should it be necessary to pulse the
juice throw follow the set up procedure below.
Use buttons
1
or
2
to scroll to either the Pulse on or Pulse off setting.
Press
3L
to enter and change the pulse time.
The LCD will flash the time setting 00.0. ( Maximum time 25.0s )
Use buttons
1
or
2
to change the time.