10.3 Weekly Clenaing
Daily cleaning plus…
Machine Part
See Section
Replacement part
Clean dispense nozzles
10.3.1
Check UV operation
10.3.2
Check drink levels
10.3.3
Clean machine floor
10.3.4
10.3.1
Clean dispense nozzles
Remove the nozzles from the white dispense nozzle holder and wipe
the ends of the metal pipe with a food grade cleaner to remove any
residue. Clean the white dispense nozzle with warm soapy water.
Dry the nozzle holder and replace the pipes into the holder.
10.3.2
Check UV working
Open the machine door
Press the flush water button
Observe the blue glow from the top of the UV filer to indicate the UV
filter is operational.
10.3.3
Check drink levels
Place a measuring jug into the bottle fill area
Press the button for a 2 ,3, 4 or 500ml bottle fill whichever is available and vend into a measuring jug.
Check the water levels and adjust the main water valve to adjust the water levels as required.
10.3.4
Clean floor
Open the machine door.
Remove the white waste bucket.
Remove any juice boxes / product from the floor.
Wipe the machine floor with warm soapy water.
Wipe under the chiller unit.
Replace the juice boxes.
Replace the white waste bucket.
Replace the brass float back into the bucket.
Glow from cap