13.6.3
►MAIN WATER
The main water for the recipe refers to the throw times to fill a bottle with water.
└―――――►
Drink Throws
└―――――►
Main Water
└―――――►
Cup not used
← Cup setting not used
└―――――►
Cup not used
← Cup setting not used
└―――――►
Bottle fill
← Water throw time
└―――――►
Delay
← Delay before the water starts
└―――――►
Pulse On
← Pulse on time
└―――――►
Pulse Off
← Pulse off time
└―――――►
Output number
← Output circuit number
13.6.3.1
Bottle fill
This setting defines the time the main water valve is open.
Use buttons
1
or
2
to scroll to the Bottle fill setting.
Press
3L
to enter and change the throw time.
The LCD will flash the time setting 00.0. ( Maximum time 60.0s )
Use buttons
1
or
2
to change the time.
Press
3L
to save the time setting.
Press cancel
3S
to exit back into ‘Door Open Mode’ to save settings to the VMC.
13.6.3.2
Delay
This setting defines the start delay time of the main water valve opening.
Use buttons
1
or
2
to scroll to the delay setting.
Press
3L
to enter and change the start delay time.
The LCD will flash the time setting 00.0. ( Maximum time 60.0s )
Use buttons
1
or
2
to change the time.
Press
3L
to save the time setting.
Press cancel
3S
to exit back into ‘Door Open Mode’ to save settings to the VMC.
13.6.3.3
Pulse ON / OFF
This setting defines the on and off duration for the main water valve. Should it be necessary to
pulse the syrup throw follow the set-up procedure below.
Use buttons
1
or
2
to scroll to either the Pulse on or Pulse off setting.
Press
3L
to enter and change the pulse time.
The LCD will flash the time setting 00.0. ( Maximum time 25.0s )
Use buttons
1
or
2
to change the time.
Press
3L
to save the time setting.
Press cancel (
3S
) to exit back into ‘Door Open Mode’ to ensure the new settings are saved
to the machine VMC.
13.6.3.4
Output number
This setting determines the output used on the VMC. This is factory set and there is no need to
change the output from the default setting.