![Westomatic H2O Hydration Station Azure Mk4 Скачать руководство пользователя страница 61](http://html1.mh-extra.com/html/westomatic/h2o-hydration-station-azure-mk4/h2o-hydration-station-azure-mk4_technical-manual_965985061.webp)
Part Number:
350092
Issue: 3
Page 61 of 125
© Copyright Westomatic Vending Services Limited 2020
All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by
any means, electrical, mechanical, photocopying, recording or otherwise, without prior permission from Westomatic Vending
Services Limited.
TRIAC TESTING
001 Select Triac
Use buttons
1
or
2
to scroll through the triac numbers until you have the triac you wish to
test. In this case triac five will be tested. Pressing button
3L
will confirm the testing of the
triac and display the following menu.
TRIAC TESTING
005 Test Triac
Press button 1 to turn ON the triac
Press button 2 to turn OFF the triac
Press 3S to cancel triac testing and return to the diagnostic menu. Repeat the above
process to test another triac.
13.2.7
►
Miscellaneous
This will allow the user to set the machine timeouts for the MDB and water inlet valve. The
sounder can be switched off in the menu.
Miscellaneous
└―――――►
MDB Timeout
← MDB Timeout for data sending
└―――――►
Master timeout
← Mater valve timeout
└―――――►
Water Filter
← Water filter drink counter
└―――――►
UV Filter
← UV filter drink counter
└―――――►
Enable sounder
← Enable sounder
13.2.7.1
Sensor Active
This function is used to enable or disable the bottle sensor to allow customers to use their own
bottle. Its function is used as shown below.
Use buttons
1
or
2
to select “Sensor Active”.
Press button
3L
to enter. The “Sensor Active” will flash.
Use buttons
1
or
2
to enable (
) or disable (
X
) the cup sensor.
Press button
3L
to enter and save the setting.
The H
2
O is fitted with a bottle sensor as standard. The sensor can be adjusted by a sensitivity
dial for different bottle types or colours.
NOTE:
The sensor must be kept clean and replaced if scratched or damaged.
13.2.8