3-114
OM 25-3503 us – Edition 4.1 * * 2503_3503b340.fm
Operation
Manual regeneration
Starting manual regeneration
Indicator light
B
illuminates and indicator light
E
flashes.
➥
Manual regeneration is possible only in this case and has to be started.
☞
Drive the machine out of the danger zone and into a safe area.
☞
Apply the parking brake.
☞
Press and hold push button
A
at least 10 seconds in position
3
.
➥
Indicator lights
B
and
C
illuminate during regeneration.
Interrupting manual regeneration
Press and hold the
Regeneration
push button at least 3 seconds in position
1
.
NOTICE
Possible damage to engine or particulate filter.
• Perform a complete regeneration cycle
NOTICE
Fire hazard in the exhaust system.
• There must be no easily flammable material in the direct vicinity of the
exhaust system, in particular near the end pipe.
• Do not perform manual regeneration in environments with easily flammable
material.
Regeneration not performed – stopping the machine
Engine power is reduced if indicator lights
B
and
F
illuminate and if indicator light
E
flashes.
Stop the engine immediately and contact a Wacker Neuson service center.
Fig. 260
Fig. 260
1
A
2
3
Fig. 261
B
C
E
F
Содержание 2503
Страница 12: ...I 10 OM 25 3503 us Edition 4 1 Ba2503_3503us4_0SIX fm Index...
Страница 40: ...1 28 OM 25 3503 us Edition 4 1 2503_3503b110 fm Introduction...
Страница 182: ...4 8 OM 25 3503 us Edition 4 1 2503_3503b410 fm Malfunctions...
Страница 230: ...5 48 OM 25 3503 us Edition 4 1 2503_3503b550 fm Wartung...
Страница 250: ...6 20 OM 25 3503 us Edition 4 1 2503_3503b610 fm Technical datac 2503 3503 long short stick...
Страница 251: ...OM 25 3503 us Edition 4 1 2503_3503b610 fm 6 21 Technical datac 3503 long short stick VDS 3503 long short stick Vario...
Страница 252: ...6 22 OM 25 3503 us Edition 4 1 2503_3503b610 fm Technical datac...