E6581697
K-33
11
Table of input terminal functions 3
Function
No.
Code Function
Action
Reference
96
FRR
Coast stop command
ON: Coast stop (Gate OFF)
OFF: Coast stop canceled
3.2.1
97
FRRN
Inversion of coast stop command
Inversion of FRR
98 FR
Forward/reverse
selection
ON:
Forward
operation command
OFF: Reverse operation command
7.2.1
99
FRN
Inversion of forward/reverse selection
Inversion of FR
100
RS
Run/Stop command
ON: Run command
OFF: Stop command
7.2.1
101
RSN
Inversion of run/Stop command
Inversion of RS
104
FCHG
Frequency setting mode forced switching
ON:
f207
(
f200
=
0
)
OFF:
fmod
5.6
105
FCHGN
Inversion of frequency setting mode forced
switching
Inversion of FCHG
106
FMTB
Frequency setting mode terminal board
ON: Terminal board (VIA) enabled
OFF: Setting of
107
FMTBN
Inversion of frequency setting mode terminal
board
Inversion of FMTB
108
CMTB
Command mode terminal board
ON: Terminal board enabled
OFF: Setting of
109
CMTBN
Inversion of command mode terminal board
Inversion of CMTB
110
PWE
Parameter editing permission
ON: Parameter editing permitted
OFF: Setting of
6.29.1
111
PWEN
Inversion of parameter editing permission
Inversion of PWE
120
FSTP1
Fast stop command 1
ON: Dynamic quick deceleration command
OFF: Forced deceleration canceled
(Note that operation is resumed when forced deceleration is
canceled)
5.4.1
121
FSTP1N
Inversion of fast stop command 1
Inversion of FSTP1
122
FSTP2
Fast stop command 2
ON: Automatic deceleration
OFF: Forced deceleration canceled
(Note that operation is resumed when forced deceleration is
canceled)
123
FSTP2N
Inversion of fast stop command 2
Inversion of FSTP2
134
TVS
Traverse permission signal
ON: Permission signal of traverse
operation
OFF: Normal operation
6.35
135
TVSN
Inversion of traverse permission signal
Inversion of TVS
136, 137
Factory specific coefficient
-
*1
140 SLOWF Forward
deceleration
ON: Forward operation with
f383
frequency
OFF: Normal operation
6.18.2
141
SLOWFN
Inversion of forward deceleration
Inversion of SLOWF
142 STOPF Forward
stop ON:
Forward
stop
OFF: Normal operation
143 STOPFN
Inversion
of
forward
stop
Inversion of STOPF
144 SLOWR Reverse
deceleration
ON: Reverse operation with
f383
frequency
OFF: Normal operation
145
SLOWRN
Inversion of reverse deceleration
Inversion of SLOWR
146 STOPR Reverse
stop ON:
Reverse
stop
OFF: Normal operation
147
STOPRN
Inversion of reverse
stop
Inversion of STOPR
148 to 151
Factory specific coefficient
-
*1
200
PWP
Parameter editing prohibition
ON: Parameter editing prohibited
OFF: Setting of
6.29.1
201
PWPN
Inversion of parameter editing prohibition
Inversion of PWP
202
PRWP
Parameter reading prohibition
ON: Parameter reading / editing prohibited
OFF: Setting of
203
PRWPN
Inversion of parameter reading prohibition
Inversion of PRWP
*1: Factory specific coefficient parameters are manufacturer setting parameters. Do not change the value of these parameters.