E6581697
K-18
11
Title
Communication
No.
Function Unit
Minimum
setting unit
Panel/Commun
ication
Adjustment range
Default
setting
User
setting
Reference
0657 Overload
alarm
level
% 1/1
10-100
50
3.5
0660 Override
addition
input selection
- -
0: Disabled
1: VIA
2: VIB
3: VIC
4:
fc
0
6.26
0661 Override
multiplication input
selection
- -
0: Disabled
1: VIA
2: VIB
3: VIC
4:
f729
0
6.26
0663 Analog
input
terminal function
selection (VIB)
-
-
0: Frequency command
1: Acceleration/deceleration time
2: Upper limit frequency
3, 4: -
5: Torque boost value
6: Stall prevention level
7: Motor electronic-thermal protection
level
8 to 10: -
11: Base frequency
0
6.27
Output
parameters
Title
Communication
No.
Function Unit
Minimum
setting unit
Panel/Commun
ication
Adjustment range
Default
setting
User
setting
Reference
0669
Logic output/pulse
train output
selection (OUT)
-
-
0: Logic output
1: Pulse train output
0
6.28.1
0676
Pulse train output
function selection
(OUT)
- -
0: Output
frequency
1: Output current
2: Frequency command
value
3: Input voltage (DC detection)
4: Output voltage (command value)
5: Input power
6: Output power
7: Torque
8: -
9: Motor cumulative load factor
10: Inverter cumulative load factor
11: PBR (Braking resistor) cumulative
load factor
12: Stator frequency
13: VIA input value
14: VIB input value
15: Fixed output 1
(output current 100% equivalent)
16: Fixed output 2
(output current 50% equivalent)
17: Fixed output 3
(Other than the output current)
18: Communication data
19: -
20: VIC input value
21, 22: -
23: PID feedback value
0
0677 Maximum
numbers
of pulse train
output
kpps
0.01/0.01 0.50-2.00
0.80