E6581697
K-25
11
Title
Communication
No.
Function Unit
Minimum
setting unit
Panel/Commun
ication
Adjustment range
Default
setting
User
setting
Reference
0810
Communication
command point
selection
- 1/1
0:
Disabled
1: Enabled
0
6.6.2
6.33.1
0811
Communication
command point 1
setting
% 1/1
0-100
0
0812
Communication
command point 1
frequency
Hz 0.1/0.01
0.0-
0.0
0813
Communication
command point 2
setting
% 1/1
0-100
100
0814
Communication
command point 2
frequency
Hz 0.1/0.01
0.0-
*1
0829
Selection of
communication
protocol
-
-
0: Toshiba inverter protocol
1: Modbus RTU protocol
0
6.33.1
0856 Number
of
motor
poles for
communication
-
-
1: 2 poles
2: 4 poles
3: 6 poles
4: 8 poles
5: 10 poles
6: 12 poles
7: 14 poles
8: 16 poles
2
0870
Block write data 1
-
-
0
0871
Block write data 2
-
-
0: No selection
1: Command information 1
2: Command information 2
3: Frequency command value
4: Output data on the terminal board
5: Analog output for communication
6: Speed command value
0
0875
Block read data 1
-
-
0
0876
Block read data 2
-
-
0
0877
Block read data 3
-
-
0
0878
Block read data 4
-
-
0
0879
Block read data 5
-
-
0: No selection
1: Status information
2: Output frequency
3: Output current
4: Output voltage
5: Alarm information
6: PID feedback value
7: Input terminal board monitor
8: Output terminal board monitor
9: VIA terminal board monitor
10: VIB terminal board monitor
11: VIC terminal board monitor
12: Input voltage (DC detection)
13: Motor speed
14: Torque
0
0880
Free notes
-
1/1
0-65530 (65535)
0
6.33.3
0898
Factory specific
coefficient 8A
- -
-
- *3
0899
Communication
function reset
- -
0:
-
1: Reset (after execution: 0)
0
6.33.1
*1: Default setting values vary depending on the setup menu setting. Refer to section 11.5.
*3: Factory specific coefficient parameters are manufacturer setting parameters. Do not change the value of these parameters.