E6581442
11
K-28
[28] Operation panel parameters [2/3]
Sensorless vector/vector with sensor (
●
:Effective, -:Ineffective)
Vector control
Title
Communi
cation
No.
Function Adjustment
range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Speed
control
Torque
control
PM
control V/f Constant Reference
0730
Operation panel frequency
setting prohibition selection
0:Permit
1:Prohibit
1/1 0
Enabled
●
/
●
●
/
●
●
●
6. 36. 1
0734
Operation panel emergency
stop operation prohibition
selection
0:Permit
1:Prohibit
1/1 0
Enabled
●
/
●
●
/
●
●
●
6. 36. 1
0735
Operation panel reset operation
prohibition selection
0:Permit
1:Prohibit
1/1 0
Enabled
●
/
●
●
/
●
●
●
6. 36. 1
0736
Prohibition of change of
/
during
operation
0:Permit
1:Prohibit
1/1 1
Enabled
●
/
●
●
/
●
●
●
6. 36. 1
0737
All key operation prohibition
0:Permit
1:Prohibit
1/1 0
Enabled
●
/
●
●
/
●
●
●
6. 36. 1
0740
Trace selection
0:Deselect, 1:At tripping, 2:At triggering
1/1
1
Enabled
●
/
●
●
/
●
●
●
6.
37
0741
Trace cycle
0:4ms, 1:20ms, 2:100ms, 3:1s, 4:10s
1/1
2
Enabled
●
/
●
●
/
●
●
●
6.
37
0742
Trace data 1
0~49
1/1
0
Enabled
●
/
●
●
/
●
●
●
6.
37
0743
Trace data 2
0~49
1/1
1
Enabled
●
/
●
●
/
●
●
●
6.
37
0744
Trace data 3
0~49
1/1
2
Enabled
●
/
●
●
/
●
●
●
6.
37
0745
Trace data 4
0~49
1/1
3
Enabled
●
/
●
●
/
●
●
●
6.
37
0748
Integrating wattmeter retention
selection
0:Disabled
1:Enabled
1/1 0
Enabled
●
/
●
●
/
●
●
●
6.
38
0749
Integrating wattmeter display
unit selection
0:1=1kWh
1:1=10kWh
2:1=100kWh
3:1=1000kWh
4:1=10000kWh
1/1 *2
Enabled
●
/
●
●
/
●
●
●
6.
38
0750
EASY key function selection
0:Quick mode/standard setting mode switching
function
1:Shortcut key:Pressing for 2 sec. to record the
parameter, pressing normally to jump
to recorded parameter (first jump to
the 1st history)
2:Operation panel/remote key:Operation panel by
ON
3:Monitor peak minimum hold trigger
1/1 0
Disabled
●
/
●
●
/
●
●
●
5.
22
0751
Quick registration parameter 1
0~999 *1
1/1
40
(AU4)
Enabled
●
/
●
●
/
●
●
●
5.
22
0752
Quick registration parameter 2
0~999 *1
1/1
15
(pt)
Enabled
●
/
●
●
/
●
●
●
5.
22
0753
Quick registration parameter 3
0~999 *1
1/1
11
(FH)
Enabled
●
/
●
●
/
●
●
●
5.
22
0754
Quick registration parameter 4
0~999 *1
1/1
9
(ACC)
Enabled
●
/
●
●
/
●
●
●
5.
22
0755
Quick registration parameter 5
0~999 *1
1/1
10
(dEC)
Enabled
●
/
●
●
/
●
●
●
5.
22
*1: The communication number of the parameter is used for this setting.
*2: Default values vary depending on the capacity.
See the table of K-48.