E6581442
L-2
12
2) Standard specifications (large capacity types) [Note 1]
Item
Specification
Voltage class
200V class
Applicable motor (kW)
55 75
Applicable motor (HP)
75 100
Type VFAS1-
Form 2550P
2750P
Output capacity
(kVA) [Note 2]
84 109
Output current
(A)
221 285
Output voltage
Three-phase 200V~240V (The maximum output voltage is equal to the input supply voltage.)
Ra
ting
Overload
current rating
150%-1 minute, 165%-2 sec.
Dynamic braking
circuit
Built-in dynamic braking drive circuit
Ele
ctr
ic
al
br
ak
in
g
Dynamic braking
resistor
An external braking resistor (optional)
Rating: Refer to 5.19.
Voltage-frequency
[Note 3]
Three-phase 200~240V-50/60Hz
Pow
er
su
pp
ly
Allowable
fluctuation
V 10% - 15% [Note 4] Frequency ±5%
Protective method
IP00 Open type (JEM1030) [Note 5]
Cooling method
Forced air-cooled
Cooling fan noise (dBA)
61 72
Color RAL7016
EMC filter
External filter (optional)
DC reactor
Attached DC reactor
Item
Specification
Voltage class
400V class
Applicable motor (kW)
90 110 132 160 200 220 280 355 400 500
Applicable motor (HP)
125 150 200 250 300 350 450 550 600 700
Type VFAS1-
Form 4900PC
4110KPC
4132KPC
4160KPC
4200KPC
4220KPC
4280KPC
4355KPC
4400KPC
4500KPC
Output capacity
(kVA) [Note 2]
136 164 197 239 295 325 419 511 578 717
Output current
(A)
179 215 259 314 387 427 550 671 759 941
Output voltage
Three-phase 380V~480V (The maximum output voltage is equal to the input supply voltage.)
Ra
ting
Overload
current rating
150%-1 minute, 165%-2 sec.
Dynamic
braking circuit
Built-in dynamic braking drive circuit
External dynamic braking circuit (optional)
Ele
ctr
ic
al
br
ak
in
g
Dynamic braking
resistor
An external braking resistor (optional)
Rating: Refer to 5.19.
Voltage-frequency
[Note 3]
[Note 6]
Three-phase 380~440V-50Hz
Three-phase 380~480V-60Hz
Pow
er
su
pp
ly
Allowable
fluctuation
V 10% - 15% [Note 4] Frequency ±5%
Protective method
IP00 Open type (JEM1030) [Note 5]
Cooling method
Forced air-cooled
Cooling fan noise (dBA)
61 72 73 73 76 76 76 76 76 78
Color RAL7016
EMC filter
Built-in
DC reactor
Attached DC reactor
Note 1: For 200V-55kW, 400V-90kW or larger model, be sure to install DC reactor.
However, this is unnecessary for DC input specifications.
Note 2: Capacity is calculated at 220V for the 200V models and at 440V for the 400V models.
Note 3: An external power supply backup available (optional) (Type: CSP002Z)
Note 4: ±10% when the inverter is used continuously (load of 100%).
Note 5: Models, 200V-18.5kW and above, and 400V-22kW and above, do not have wiring port covers. They have
large openings, but there is no space to bend the external cables inside the unit.
Note 6: Three-phase 380~480V-50/60Hz for 4900PC
Содержание TOSVERT VF-AS1 Series
Страница 238: ...E6581442 I 7 9 ...
Страница 261: ...E6581442 J 13 10 VFAS1 4200KPC 4280KPC VFAS1 4355KPC 4400KPC 4500KPC ...
Страница 321: ...E6581442 M 3 13 Continued overleaf ...