E6581442
E-41
5
Minimum resistance of connectable braking resistors
The minimum allowable resistance values of the externally connectable braking resistors are listed in the table
below.
Do not connect braking resistors with smaller resultant resistance than the listed minimum allowable resistance
values.
(For 200kW or greater models, a dynamic braking resistor drive unit (optional separate unit) is needed.)
200V Class
400V Class
Inverter
Related output capacity
(kW)
Resistance of
standard option
Minimum allowable
resistance
Resistance of
standard option
Minimum allowable
resistance
0.4 200
Ω
50
Ω
– –
0.75 200
Ω
50
Ω
200
Ω
60
Ω
1.5 75
Ω
35
Ω
200
Ω
60
Ω
2.2 75
Ω
20
Ω
200
Ω
60
Ω
3.7/4.0 40
Ω
16
Ω
160
Ω
40
Ω
5.5 20
Ω
11
Ω
80
Ω
30
Ω
7.5 15
Ω
8
Ω
60
Ω
20
Ω
11 10
Ω
5
Ω
40
Ω
20
Ω
15 7.5
Ω
5
Ω
30
Ω
13.3
Ω
18.5 7.5
Ω
3.3
Ω
30
Ω
13.3
Ω
22 3.3
Ω
3.3
Ω
15
Ω
13.3
Ω
30 3.3
Ω
2.5
Ω
13.3
Ω
10
Ω
37 2
Ω
1.7
Ω
8
Ω
6.7
Ω
45 2
Ω
1.7
Ω
8
Ω
5
Ω
55 2
Ω
1.7
Ω
8
Ω
5
Ω
75 1.7
Ω
1.3
Ω
8
Ω
3.3
Ω
90 –
–
3.7
Ω
2.5
Ω
110 –
–
3.7
Ω
1.9
Ω
132 –
–
3.7
Ω
1.9
Ω
160 –
–
3.7
Ω
1.9
Ω
200 –
–
1.9
Ω
1
Ω
220 –
–
1.9
Ω
1
Ω
280 –
–
1.4
Ω
1
Ω
355
–
–
0.95
Ω
0.7
Ω
400
–
–
0.95
Ω
0.7
Ω
500
–
–
0.7
Ω
0.7
Ω
Содержание TOSVERT VF-AS1 Series
Страница 238: ...E6581442 I 7 9 ...
Страница 261: ...E6581442 J 13 10 VFAS1 4200KPC 4280KPC VFAS1 4355KPC 4400KPC 4500KPC ...
Страница 321: ...E6581442 M 3 13 Continued overleaf ...