![Toshiba TOSVERT VF-AS1 Series Скачать руководство пользователя страница 277](http://html.mh-extra.com/html/toshiba/tosvert-vf-as1-series/tosvert-vf-as1-series_instruction-manual_424758277.webp)
E6581442
11
K-16
[18] Motor constant
Sensorless vector/vector with sensor (
●
:Effective, -:Ineffective)
Vector control
Title
Communi
cation
No.
Function Adjustment
range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Speed
control
Torque
control
PM
control V/f Constant Reference
0400 Auto-tuning
1
0:No auto-tuning
1:Initialize motor constant (0 after execution)
2:Continue operation continued after auto-tuning (0
after execution)
3:Auto-tuning by input terminal signal
4:Motor constant auto calculation (0 after
execution)
1/1 0
Disabled
●
/
●
●
/
●
- - 6.
22
0401 Slip
frequency
gain
0~150%
1/1
70 Enabled
●
/- - - -
6.
22
0402 Auto-tuning
2
0:Disabled
1:Self-cooled motor
2:Forced air-cooled motor
1/1 0
Disabled
●
/
●
●
/
●
- - 6.
22
0405
Motor rated capacity (motor
name plate)
0.10~630.0kW 0.01/0.01
*1
Disabled
●
/
●
●
/
●
- - 6.
22
0406
Motor rated current (motor
name plate)
0.1~2000A 0.1/0.1
*1
Disabled
●
/
●
●
/
●
- - 6.
22
0407
Motor rated rotational speed
(motor name plate)
100~60000min-1 *2
1/1
*1
Disabled
●
/
●
●
/
●
- - 6.
22
0410
Motor constant 1 (torque boost) 0.0~30.0%
0.1/0.1
*1
Enabled
●
/
●
●
/
●
- - 6.
22
0411
Motor constant 2 (no load
current)
10~90% 1/1
*1
Disabled
●
/
●
●
/
●
- - 6.
22
0412
Motor constant 3 (leak
inductance)
0~200(
×
0.1%) 1/1
*1
Disabled
●
/
●
●
/
●
- - 6.
22
0413
Motor constant 4 (rated slip)
0.1~25.0%
0.1/0.1
*1
Disabled
●
/
●
●
/
●
- - 6.
22
0415
Exciting strengthening
coefficient
100~130% 1/1
100
Disabled
●
/
●
●
/
●
- - 6.
23
0416
Stall prevention factor
10~250
1/1
100
Disabled
●
/
●
●
/
●
- - 6.
23
*1: Default values vary depending on the capacity.
See the table of K-46.
*2: If the speed of rotation is set at 10,000min
-1
or more, the error messages
and
(if the speed of rotation is set at 10,000min
-1
) are displayed alternately.
[19] Torque control [1/2]
Sensorless vector/vector with sensor (
●
:Effective, -:Ineffective)
Vector control
Title
Communi
cation
No.
Function Adjustment
range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Speed
control
Torque
control
PM
control V/f Constant Reference
0420 Torque
command
selection
1:VI/II (voltage/current input)
2:RR/S4 (potentiometer/voltage input)
3:RX (voltage input)
4:Operation panel input enabled (including
LED/LCD option input)
5:2-wire RS485 communication input
6:4-wire RS485 communication input
7:Communications option input enabled
8:Optional AI1 (differential current input)
1/1 3
Enabled
-
●
/
●
- - *1
0421 Torque
reference
filter
0~1000ms
1/1 0
Enabled
-
●
/
●
- - *1
0423
Tension torque bias input
selection (torque control)
0:Disabled, 1~8 (same as
) 1/1
0
Enabled
-
●
/
●
-
-
6. 24. 3
*1:
For details, refer to Instruction Manual (E6581331) specified in Section 6.42.