E6581442
H-3
8
(Continued)
Commun
ication
No.
Item displayed
Key
operated
LED
display
Description
FE08 CPU1
version
The version of the CPU1 is displayed.
FE73 CPU2
version
The version of the CPU2 is displayed.
FE10
Past trip 1
Past trip 1 (displayed alternately at 0.5-sec. intervals)
FE11
Past trip 2
Past trip 2 (displayed alternately at 0.5-sec. intervals)
FE12
Past trip 3
Past trip 3 (displayed alternately at 0.5-sec. intervals)
FE13
Past trip 4
Past trip 4 (displayed alternately at 0.5-sec. intervals)
FE79
Part replacement
alarm information
The ON/OFF status of each of the cooling fan, circuit
board capacitor, main circuit capacitor or part
replacement alarm of cumulative operation time is
displayed in bits.
ON:
OFF:
FE14
Cumulative
operation time
The cumulative operation time is displayed.
(Indication of 0.1 represents 10 hours.)
Default display
mode
[Note 1]
The operation frequency is displayed (during operation).
Note 1: Press the
keys to change items displayed in the status monitor mode.
Note 2: Contents of status indications of *1, *2, *3, *4, *5, *6, *7, *8, and *9 can be selected from 44 kinds of
information.
Contents of status indications that are set up at
(standard monitor display selection) and
~
(status monitor 1 to 8 display selection) are displayed.
Unit of current and voltage indications can be changed from % to A (ampere)/V (volt) and vice versa
respectively.
Refer to Section 5.15.
Note 3: Indicated input voltage is DC voltage just after input voltage is rectified multiplied by 1
2 .
Note 4: The number of bars displayed varies depending on the setting of
(logic output/pulse train output
selection.)
The bar representing the OUT1 terminal is displayed only when logic output function is assigned to it.
If
=
: The bar representing OUT1 is displayed.
If
=
: The bar representing OUT1 is not displayed.
Note 5: Past rip records are displayed in the following sequence: 1 (latest trip record)
2
3
4 (oldest trip record).
If there is no trip record,
is displayed.
Details on past trip record 1, 2, 3 or 4 can be displayed by pressing the
ENT
key when past trip 1, 2, 3 or
4 is displayed.
For more details, refer to Section 8.2.2.
Note 6: The part replacement alarm is displayed based on the value calculated from the annual average ambient
temperature, operation time and load current specified using
.
Use this alarm as a guide only, since it is based on a rough estimation.
Note 7: The cumulative operation time increments only when the machine is in operation.
MODE
Cooling fan
Cumulative
operation time
Control circuit board
capacitor
Main circuit capacitor
[Note 6]
[Note 5]
[Note 7]
[Note 5]
[Note 5]
[Note 5]