![Toshiba TOSVERT VF-AS1 Series Скачать руководство пользователя страница 150](http://html.mh-extra.com/html/toshiba/tosvert-vf-as1-series/tosvert-vf-as1-series_instruction-manual_424758150.webp)
E6581442
F-34
6
- Warning -
• When switching to commercial power, make sure that the direction in which the motor rotates when operated
on commercial power agrees with the forward direction when operated via the inverter.
• Do not select any option (
=
) of
(reverse rotation prohibition selection) that prohibits forward
rotation. Or it becomes impossible to switch to commercial power, because the motor cannot rotate in the
forward direction.
6.20 PID
control
:
PID control switching
: PID control feedback control signal selection
: Delay filter
: Proportional (P) gain
: Integral (I) gain
: PID deviation upper limit
: PID deviation lower limit
:
Differential (D) gain
: Process upper limit
: Process lower limit
: PID control waiting time
: PID output upper limit
: PID output lower limit
: Process increasing rate
(speed type PID control)
: Process decreasing rate
(speed type PID control)
: PID output dead band
⇒
For details, see instruction Manual(E6581329)specified in Section.
[Parameter setting]
Title
Function
Adjustment range
Default setting
PID control switching
:No PID control
:Process type PID control
(temp./pressure, etc.) operation
2:Speed type PID control
(potentiometer, etc.) operation
PID control feedback control signal
selection
:Deviation input (no feedback
input)
:VI/II (voltage/current input)
:RR/S4 (potentiometer/voltage
input)
:RX (voltage input)
:Optional AI1 (differential current
input)
:Optional AI2 (voltage/current
input)
: PG feedback option
Delay
filter
~
Proportional (P) gain
1~
Integral (I) gain
~
PID deviation upper limit
~
Hz
*1
PID deviation lower limit
~
Hz
*1
Differential (D) gain
~
Process upper limit
~
Hz
*1
Process lower limit
~
Hz
PID control waiting time
~
sec.
PID output upper limit
~
Hz
*1
PID output lower limit
~
Hz
Process increasing rate (speed type
PID control)
~
Process decreasing rate (speed type
PID control)
~
PID output dead band
~
*
1
: Inverter with a model number ending with -WN1:
-WP1:
・
Function
Using feedback signals (4 to 20mA, 0 to 10V) from a detector, process control can be exercised, for
example, to keep the airflow, amount of flow or pressure constant.
Содержание TOSVERT VF-AS1 Series
Страница 238: ...E6581442 I 7 9 ...
Страница 261: ...E6581442 J 13 10 VFAS1 4200KPC 4280KPC VFAS1 4355KPC 4400KPC 4500KPC ...
Страница 321: ...E6581442 M 3 13 Continued overleaf ...