Selection of wiring materials and devices
Wire size
Main circuit
Input terminal
(R, S, T)
Output terminal
(U, V, W)
DC terminal
Braking resistor/
Braking unit
(optional) (*4)
Earth cable
Voltage
class
Applicable
motor
[kW]
Inverter model
AWG
(*5)
mm
2
(*6)
AWG
(*5)
mm
2
(*6)
AWG
(*5)
mm
2
(*6)
AWG
(*5)
mm
2
(*6)
AWG
(*5)
mm
2
(*7)
0.4 VFAS1-2004PL
14
1.5
14
1.5
14
1.5
14
1.5
14
2.5
0.75 VFAS1-2007PL
14 1.5 14 1.5 14 1.5
14
1.5
14
2.5
1.5 VFAS1-2015PL
14
1.5
14
1.5
12
1.5
14
1.5
14
2.5
2.2 VFAS1-2022PL
12
1.5
12
1.5
10
2.5
14
1.5
14
2.5
3.7/4.0 VFAS1-2037PL 10
4
10
4
8
6 14 1.5 12 4
5.5 VFAS1-2055PL
8 6 8 6 6 10
14
1.5
10
6
7.5 VFAS1-2075PL
8 10 8 10 4 16
12
2.5
10
10
11 VFAS1-2110PM
4 16 4
16
3
16
10
4
10
16
15 VFAS1-2150PM
4 25 4
25
1
25
8
6
10
16
18.5 VFAS1-2185PM
3 25 3 25 1/0 35 8
10 8 16
22 VFAS1-2220PM
2 25 2
25
2/0
35
6
16
8
16
30 VFAS1-2300PM
2/0
50
2/0
50
4/0
70
4
25
6
25
37 VFAS1-2370PM
3/0
70
3/0
70
250MCM
95 3 35 6 35
45 VFAS1-2450PM
4/0
70
4/0
70
300MCM
95 2 50 6 35
55 VFAS1-2550P
3/0×2
70×2
3/0×2
120 4/0×2
95×2
1/0 50 2
70
200V
class
75 VFAS1-2750P
4/0×2
95×2
250MCM×2
70×2
300MCM×2 120×2
1/0 35×2 2
95
0.75 VFAS1-4007PL
14 1.5 14 1.5 14 1.5
14
1.5
14
2.5
1.5 VFAS1-4015PL
14
1.5
14
1.5
14
1.5
14
1.5
14
2.5
2.2 VFAS1-4022PL
14
1.5
14
1.5
14
1.5
14
1.5
14
2.5
3.7/4.0 VFAS1-4037PL 12 1.5 12 1.5 10 2.5 14 1.5 14 2.5
5.5 VFAS1-4055PL
10
2.5
10
2.5
8 4
14
1.5
12
2.5
7.5 VFAS1-4075PL
10 4 10 4 8 6
14
1.5
12
4
11 VFAS1-4110PL
8 6 8 6 6
10
14
1.5
10
6
15 VFAS1-4150PL
6
10
6
10
4
16
12
2.5
10
10
18.5 VFAS1-4185PL
6 10 6 10 4 16
10
2.5
10
10
22 VFAS1-4220PL
6
10
6
10
4
16
10
4
10
10
30 VFAS1-4300PL
4
16
4
16
2
25
8
6
10
16
37 VFAS1-4370PL
3
25
3
25
1
35
8
10
8
16
45 VFAS1-4450PL
1
35
1
35
2/0
50
6
16
8
16
55 VFAS1-4550PL
1/0
50
1/0
50
3/0
70
6
16
6
25
75 VFAS1-4750PL
3/0
70
3/0
70
250MCM
95 3 35 6 35
90 VFAS1-4900PC
1/0×2
70×2
1/0×2
95
1/0×2
95×2
1/0
35
2
70
110
VFAS1-4110KPC
3/0×2
95×2
3/0×2
120 2/0×2
120×2
1/0 50 2 95
132
VFAS1-4132KPC
4/0×2
95×2
4/0×2
150 4/0×2
120×2
4/0 70 1/0 95
160
VFAS1-4160KPC 300MCM×2 120×2 300MCM×2
95×2
350MCM×2 150×2
4/0 95 1/0 120
200
VFAS1-4200KPC
4/0×3
150×2
4/0×3
120×2
3/0×3
150×3 300MCM 150 1/0 150
220
VFAS1-4220KPC 250MCM×3 150×3 250MCM×3 120×2
4/0×3
150×3 300MCM 150 2/0 150
280
VFAS1-4280KPC 350MCM×3 150×3 350MCM×3 185×2 300MCM×3 150×4 300MCM 150
3/0
120×2
355
VFAS1-4355KPC 400MCM
×2×2 (*6)
120×2×2
(*6)
400MCM×4 150×3 500MCM×3 185×4 350MCM×2 185×2 4/0 120×2
400
VFAS1-4400KPC 500MCM
×2×2 (*6)
150×2×2
(*6)
500MCM×4 185×3 500MCM×4 185×4
(*5)
350MCM×2 185×2 4/0 150×2
400V
class
500
VFAS1-4500KPC 400MCM
×3×2 (*6)
150×3×2
(*6)
400MCM×5 185×4 500MCM×4 180×4
(*5)
350MCM×2 185×2 250MCM 150×2
(*1): The recommended cable size is that of the cable (e.g. 600V class, HIV cable) with continuous maximum permissible temperature of 75°C. Ambient
temperature is 40°C or less and the wiring distance is 30m or less.
(*2): For the control circuit, use shielded wires whose size (cross-section) is 0.75 mm
2
or more.
(*3): For the earth cable, use wires larger than the specified ones in size (cross-section).
(*4): Recommended wire size for an optional braking resistor. Refer to 5.19 for use of external braking resistor.
(*5): This cable size is conformity to UL508C.
(*6): This cable size is conformity to IEC60364-5-52.
(*7): This cable size is conformity to IEC60364-5-54.
(*8): The recommended cable is 600V class HIV cable with permissible temperature of 90°C.
(*9): The number refers to a cable composition. For example, in the case of “120×2×2”: 120×2×2
Number of cables connected in parallel on the terminal board
Number of cables connected to each terminal board
Wire size 120mm
2
Warning
Содержание TOSVERT VF-AS1 Series
Страница 238: ...E6581442 I 7 9 ...
Страница 261: ...E6581442 J 13 10 VFAS1 4200KPC 4280KPC VFAS1 4355KPC 4400KPC 4500KPC ...
Страница 321: ...E6581442 M 3 13 Continued overleaf ...