E6581442
11
K-20
[22] Acceleration/deceleration 2 [2/2]
Sensorless vector/vector with sensor (
●
:Effective, -:Ineffective)
Vector control
Title
Communi
cation
No.
Function Adjustment
range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Speed
control
Torque
control
PM
control V/f Constant Reference
0509
Deceleration S-pattern upper
limit adjustment
0~50% 1/1
10
Enabled
●
/
●
-
●
●
6. 30. 1
0510
Acceleration time 3
0.1~6000 sec.
0.1/0.1 *2
*1
Enabled
●
/
●
-
●
●
6. 30. 1
0511
Deceleration time 3
0.1~6000 sec.
0.1/0.1 *2
*1
Enabled
●
/
●
-
●
●
6. 30. 1
0512
Acceleration/ deceleration 3
pattern
0:Straight, 1:S-pattern 1, 2:S-pattern 2
1/1
0
Enabled
●
/
●
-
●
●
6. 30. 1
0513
Acceleration/deceleration
switching frequency 2
0.0~
Hz
0.1/0.01
0.0
Enabled
●
/
●
-
●
●
6. 30. 1
0514
Acceleration time 4
0.1~6000 sec.
0.1/0.1 *2
*1
Enabled
●
/
●
-
●
●
6. 30. 1
0515
Deceleration time 4
0.1~6000 sec.
0.1/0.1 *2
*1
Enabled
●
/
●
-
●
●
6. 30. 1
0516
Acceleration/ deceleration 4
pattern
0:Straight, 1:S-pattern 1, 2:S-pattern 2
1/1
0
Enabled
●
/
●
-
●
●
6. 30. 1
0517
Acceleration/deceleration
switching frequency 3
0.0~
Hz
0.1/0.01
0.0
Enabled
●
/
●
-
●
●
6. 30. 1
*1: Default values vary depending on the capacity.
See the table of K-48.
*2: Changing the parameter
enables to set to 0.01 sec. (adjustment range: 0.01~600.0 sec.).
[23] Pattern operation [1/3]
Sensorless vector/vector with sensor (
●
:Effective, -:Ineffective)
Vector control
Title
Communi
cation
No.
Function Adjustment
range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Speed
control
Torque
control
PM
control V/f Constant Reference
0520
Pattern operation selection
0:Disabled
1:Enabled (setting in units of seconds)
2:Enabled (setting in units of minutes)
1/1 0
Disabled
●
/
●
-
●
●
6.
31
0521
Pattern operation mode
0:Pattern operation reset when system stops
operation
1:Pattern operation continued even after system
stops operation
1/1 0
Disabled
●
/
●
-
●
●
6.
31
0522
Number of repetitions of pattern
group 1
1~254, 255:Successive
1/1
1
Disabled
●
/
●
-
●
●
6.
31
0523
Pattern group 1 selection 1
0:Skip, 1~15
1/1
0
Disabled
●
/
●
-
●
●
6.
31
0524
Pattern group 1 selection 2
0:Skip, 1~15
1/1
0
Disabled
●
/
●
-
●
●
6.
31
0525
Pattern group 1 selection 3
0:Skip, 1~15
1/1
0
Disabled
●
/
●
-
●
●
6.
31
0526
Pattern group 1 selection 4
0:Skip, 1~15
1/1
0
Disabled
●
/
●
-
●
●
6.
31
0527
Pattern group 1 selection 5
0:Skip, 1~15
1/1
0
Disabled
●
/
●
-
●
●
6.
31
0528
Pattern group 1 selection 6
0:Skip, 1~15
1/1
0
Disabled
●
/
●
-
●
●
6.
31
0529
Pattern group 1 selection 7
0:Skip, 1~15
1/1
0
Disabled
●
/
●
-
●
●
6.
31
0530
Pattern group 1 selection 8
0:Skip, 1~15
1/1
0
Disabled
●
/
●
-
●
●
6.
31
0531
Number of repetitions of pattern
group 2
1~254, 255:Successive
1/1
1
Disabled
●
/
●
-
●
●
6.
31
0532
Pattern group 2 selection 1
0:Skip, 1~15
1/1
0
Disabled
●
/
●
-
●
●
6.
31
0533
Pattern group 2 selection 2
0:Skip, 1~15
1/1
0
Disabled
●
/
●
-
●
●
6.
31
0534
Pattern group 2 selection 3
0:Skip, 1~15
1/1
0
Disabled
●
/
●
-
●
●
6.
31
0535
Pattern group 2 selection 4
0:Skip, 1~15
1/1
0
Disabled
●
/
●
-
●
●
6.
31
0536
Pattern group 2 selection 5
0:Skip, 1~15
1/1
0
Disabled
●
/
●
-
●
●
6.
31
Содержание TOSVERT VF-AS1 Series
Страница 238: ...E6581442 I 7 9 ...
Страница 261: ...E6581442 J 13 10 VFAS1 4200KPC 4280KPC VFAS1 4355KPC 4400KPC 4500KPC ...
Страница 321: ...E6581442 M 3 13 Continued overleaf ...