K-19
E6581442
11
[21] Adjustment parameters [2/2]
Sensorless vector/vector with sensor (
●
:Effective, -:Ineffective)
Vector control
Title
Communi
cation
No.
Function Adjustment
range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Speed
control
Torque
control
PM
control V/f Constant Reference
0469
Overvoltage limit constant
0: Automatic, 1~1000ms
1/1
0
Disabled
-/-
-/-
-
●
6.14.2
0470
VI/II input bias
0~255
1/1
*1
Enabled
●
/
●
●
/
●
●
●
6.
28
0471 VI/II
input
gain
0~255
1/1
*1 Enabled
●
/
●
●
/
●
●
●
6.
28
0472 RR/S4
input
bias
0~255
1/1
*1 Enabled
●
/
●
●
/
●
●
●
6.
28
0473
RR/S4 input gain
0~255
1/1
*1
Enabled
●
/
●
●
/
●
●
●
6.
28
0474 RX
input
bias
0~255
1/1
*1 Enabled
●
/
●
●
/
●
●
●
6.
28
0475
RX input gain
0~255
1/1
*1
Enabled
●
/
●
●
/
●
●
●
6.
28
0476 Optional
AI1
input
bias
0~255
1/1
*1 Enabled
●
/
●
●
/
●
●
●
6.
28
0477
Optional AI1 input gain
0~255
1/1
*1
Enabled
●
/
●
●
/
●
●
●
6.
28
0478 Optional
AI2
input
bias
0~255
1/1
*1 Enabled
●
/
●
●
/
●
●
●
6.
28
0479
Optional AI2 input gain
0~255
1/1
*1
Enabled
●
/
●
●
/
●
●
●
6.
28
0495
Max output voltage modulation
rate
0:Standard
1:Straight 100%
2:102.5%
3:105%
1/1 0
Disabled
●
/
●
●
/
●
●
●
6.27.3
0498
PM motor constant 1 (d axis
inductance)
0~100% 0.1/0.1
10.0
Disabled
-
-
●
- 6.
29
0499
PM motor constant 2 (q axis
inductance)
0~100% 0.1/0.1
10.0
Disabled
-
-
●
- 6.
29
*1:
Settings vary from unit to unit. Even if
is set to
, no change is made to these values.
[22] Acceleration/deceleration 2 [1/2]
Sensorless vector/vector with sensor (
●
:Effective, -:Ineffective)
Vector control
Title
Communi
cation
No.
Function Adjustment
range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Speed
control
Torque
control
PM
control V/f Constant Reference
0500
Acceleration time 2
0.1~6000 sec.
0.1/0.1 *2
*1
Enabled
●
/
●
-
●
●
6. 30. 1
0501
Deceleration time 2
0.1~6000 sec.
0.1/0.1 *2
*1
Enabled
●
/
●
-
●
●
6. 30. 1
0502
Acceleration/deceleration 1
pattern
0:Straight, 1:S-pattern 1, 2:S-pattern 2
1/1
0
Enabled
●
/
●
-
●
●
6. 30. 1
0503
Acceleration/deceleration 2
pattern
0:Straight, 1:S-pattern 1, 2:S-pattern 2
1/1
0
Enabled
●
/
●
-
●
●
6. 30. 1
0504
Panel acceleration/deceleration
selection
1:Acceleration/deceleration 1
2:Acceleration/deceleration 2
3:Acceleration/deceleration 3
4:Acceleration/deceleration 4
1/1
1
Enabled
●
/
●
-
●
●
6. 30. 1
0505
Acceleration/deceleration
switching frequency 1
0.0~
Hz
0. 1/0.01
0.0
Enabled
●
/
●
-
●
●
6. 30. 1
0506
Acceleration S-pattern lower
limit adjustment
0~50% 1/1
10
Enabled
●
/
●
-
●
●
6. 30. 1
0507
Acceleration S-pattern upper
limit adjustment
0~50% 1/1
10
Enabled
●
/
●
-
●
●
6. 30. 1
0508
Deceleration S-pattern lower
limit adjustment
0~50% 1/1
10
Enabled
●
/
●
-
●
●
6. 30. 1
*1: Default values vary depending on the capacity.
See the table of K-48.
*2: Changing the parameter
enables to set to 0.01 sec. (adjustment range: 0.01~600.0 sec.).
Содержание TOSVERT VF-AS1 Series