E6581442
11
K-8
[5] V/f 5-point setting
Sensorless vector/vector with sensor (
●
:Effective, -:Ineffective)
Vector control
Title
Communi
cation
No.
Function Adjustment
range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Speed
control
Torque
control
PM
control
V/f Reference
0190
V/f 5-point setting VF1
frequency
0.0~
Hz
0.1/0.01
0.0
Disabled
-
-
-
●
5.
6
0191
V/f 5-point setting VF1 voltage
0.0~100.0%
0.1/0.01
0.0
Disabled
-
-
-
●
5.
6
0192
V/f 5-point setting VF2
frequency
0.0~
Hz
0.1/0.01
0.0
Disabled
-
-
-
●
5.
6
0193
V/f 5-point setting VF2 voltage
0.0~100.0%
0.1/0.01
0.0
Disabled
-
-
-
●
5.
6
0194
V/f 5-point setting VF3
frequency
0.0~
Hz
0.1/0.01
0.0
Disabled
-
-
-
●
5.
6
0195
V/f 5-point setting VF3 voltage
0.0~100.0%
0.1/0.01
0.0
Disabled
-
-
-
●
5.
6
0196
V/f 5-point setting VF4
frequency
0.0~
Hz
0.1/0.01
0.0
Disabled
-
-
-
●
5.
6
0197
V/f 5-point setting VF4 voltage
0.0~100.0%
0.1/0.01
0.0
Disabled
-
-
-
●
5.
6
0198
V/f 5-point setting VF5
frequency
0.0~
Hz
0.1/0.01
0.0
Disabled
-
-
-
●
5.
6
0199
V/f 5-point setting VF5 voltage
0.0~100.0%
0.1/0.01
0.0
Disabled
-
-
-
●
5.
6
[6] Speed/torque reference gain/bias setup [1/2]
Sensorless vector/vector with sensor (
●
:Effective, -:Ineffective)
Vector control
Title
Communi
cation
No.
Function Adjustment
range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Speed
control
Torque
control
PM
control
V/f Reference
0200
Frequency priority selection
0:
/
terminal switching (input
terminal function selection 104, 105)
1:
/
frequency switching (switching
with
)
1/1 0
Enabled
●
/
●
-
●
●
6.
6.
1
0201
VI/II input point 1 setting
0~100%
1/1
0
Enabled
●
/
●
●
/
●
●
●
7.
3.
2
0202
VI/II input point 1 frequency
0.0~
Hz
0.1/0.01
0.0
Enabled
●
/
●
-
●
●
7.
3.
2
0203
VI/II input point 2 setting
0~100%
1/1
100
Enabled
●
/
●
●
/
●
●
●
7.
3.
2
0204 VI/II input point 2 frequency
0.0~
Hz
0.1/0.01
*1
Enabled
●
/
●
-
●
●
5. 11
0205
VI/II input point 1 rate
0~250% (for torque control etc.)
1/0.01
0
Enabled
●
/
●
●
/
●
- - *2
0206
VI/II input point 2 rate
0~250% (for torque control etc.)
1/0.01
100
Enabled
●
/
●
●
/
●
- - *2
0207
Frequency setting mode
selection 2
Same as
(1~13)
1/1
1
Disabled
●
/
●
-
●
●
6.
6.
1
0208
Speed command priority
switching frequency
0.1~
Hz
0.1/0.01
0.1
Enabled
●
/
●
-
●
●
6.
6.
1
0209
Analog input filter
0:No filter
1:Filter approx. 10ms
2:Filter approx. 15ms
3:Filter approx. 30ms
4:Filter approx. 60ms
1/1 0
Enabled
●
/
●
●
/
●
●
●
7.
2.
4
0210
RR/S4 input point 1 setting
0~100%
1/1
0
Enabled
●
/
●
●
/
●
●
●
7.
3.
1
0211
RR/S4 input point 1 frequency
0.0~
Hz
0.1/0.01
0.0
Enabled
●
/
●
-
●
●
7.
3.
1
This parameter moves to a fundamental parameter.
*1: Inverter with a model number ending with -WN1: 60.0 -WP1: 50.0