E6581442
F-54
6
Setting parameters
a) Operating method: Terminal input
Set the command mode selection
to
.
b) Use the S2 and S3 terminals for switching. (Instead, other terminals may be used.)
S2: Acceleration/deceleration switching signal 1
S3: Acceleration/deceleration switching signal 2
Title
Function
Adjustment range
Setting value
Input terminal function selection 6 (S2)
~
(Acceleration/deceleration
switching signal 1)
Input terminal function selection 7 (S3)
~
(Acceleration/deceleration
switching signal 2)
Acceleration/deceleration pattern
Acceleration/deceleration patterns can be selected individually, using the acceleration/deceleration 1, 2, 3 and 4
parameters.
1) Straight acceleration/deceleration
2) S-pattern acceleration/deceleration 1
3) S-pattern acceleration/deceleration 2
Title
Function
Adjustment range
Default setting
Acceleration/deceleration 1 pattern
:Straight,
:S-pattern 1,
:S-pattern 2
Acceleration/deceleration 2 pattern
:Straight,
:S-pattern 1,
:S-pattern 2
Acceleration S-pattern lower limit
adjustment
~
%
Acceleration S-pattern upper limit
adjustment
~
%
Deceleration S-pattern lower limit
adjustment
~
%
Deceleration S-pattern upper limit
adjustment
~
%
Acceleration/deceleration 3 pattern
:Straight,
:S-pattern 1,
:S-pattern 2
Acceleration/deceleration 4 pattern
:Straight,
:S-pattern 1,
:S-pattern 2
1) Straight acceleration/deceleration
A general acceleration/deceleration pattern.
This pattern can usually be used.
Output frequency [Hz]
Maximum frequency
Time [s]
0
2) S-pattern acceleration/deceleration 1
Select this pattern to accelerate/decelerate the motor rapidly to a high-speed region with an output frequency of
60Hz or more or to minimize the shocks applied during acceleration/deceleration. This pattern is suitable for
conveyer machines.
Actual acceleration time
×
%
×
%
Time [s]
Output frequency [Hz]
0
Maximum frequency
Set frequency
Actual deceleration time
Maximum frequency
Set frequency
×
%
Time [s]
Output frequency [Hz]
0
×
%
Both the S-pattern lower-limit setting (
,
) and the S-pattern upper limit setting (
,
) affect all acceleration/deceleration pattern settings.
Содержание TOSVERT VF-AS1 Series
Страница 238: ...E6581442 I 7 9 ...
Страница 261: ...E6581442 J 13 10 VFAS1 4200KPC 4280KPC VFAS1 4355KPC 4400KPC 4500KPC ...
Страница 321: ...E6581442 M 3 13 Continued overleaf ...