![Toshiba TOSVERT VF-AS1 Series Скачать руководство пользователя страница 278](http://html.mh-extra.com/html/toshiba/tosvert-vf-as1-series/tosvert-vf-as1-series_instruction-manual_424758278.webp)
K-17
E6581442
11
[19] Torque control [2/2]
Sensorless vector/vector with sensor (
●
:Effective, -:Ineffective)
Vector control
Title
Communi
cation
No.
Function Adjustment
range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Speed
control
Torque
control
PM
control V/f Constant Reference
0424
Load sharing gain input
selection
0:Disabled, 1~8 (same as
) 1/1
0
Enabled
-
●
/
●
-
-
6. 24. 3
0425
Forward speed limit input
selection
0:Disabled
1:VI/II (voltage/current input)
2:RR/S4 (potentiometer/voltage input)
3:RX (voltage input)
4:
enabled
1/1 0
Enabled
-
●
/
●
- - *1
0426
Forward speed limit input level
0.0~
Hz
0.1/0.01
*2
Enabled
-
●
/
●
- - *1
0427
Reverse speed limit input
selection
0:Disabled
1:VI/II (voltage/current input)
2:RR/S4 (potentiometer/voltage input)
3:RX (voltage input)
4:
enabled
1/1 0
Enabled
-
●
/
●
- - *1
0428
Reverse speed limit input level
0.0~
Hz
0.1/0.01
*2
Enabled
-
●
/
●
- - *1
0430
Speed limit (torque = 0) center
value reference selection
0:Disabled
1:VI/II (voltage/current input)
2:RR/S4 (potentiometer/voltage input)
3:RX (voltage input)
4:
enabled
1/1 0
Enabled
-
●
/
●
- - *1
0431
Speed limit (torque = 0) center
value
0.0~
Hz
0.1/0.01
0.0
Enabled
-
●
/
●
- - *1
0432
Speed limit (torque = 0) band
0.0~
Hz
0.1/0.01
0.0
Enabled
-
●
/
●
- - *1
0435
Prohibition of rotation in any
direction other than the
specified one (F or R)
0:Disabled
1:Enabled
1/1 0
Enabled
-
●
/
●
- - *1
*1:
For details, refer to Instruction Manual (E6581331) specified in Section 6.42. *2: Inverter with a model number ending with -WN1: 60.0 -WP1: 50.0
[20] Torque limit [1/2]
Sensorless vector/vector with sensor (
●
:Effective, -:Ineffective)
Vector control
Title
Communi
cation
No.
Function Adjustment
range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Speed
control
Torque
control
PM
control V/f Constant Reference
0440
Power running torque limit 1
selection
1:VI/II (voltage/current input)
2:RR/S4 (potentiometer/voltage input)
3:RX (voltage input)
4:
1/1 4
Enabled
●
/
●
●
/
●
●
-
6. 25. 1
0441
Power running torque limit 1
level
0.0~249.9%, 250.0:Disabled
0.1/0.01
250.0
Enabled
●
/
●
●
/
●
●
-
6. 25. 1
0442
Regenerative braking torque
limit 1 selection
1:VI/II (voltage/current input)
2:RR/S4 (potentiometer/voltage input)
3:RX (voltage input)
4:
1/1 4
Enabled
●
/
●
●
/
●
●
-
6. 25. 1
0443
Regenerative braking torque
limit 1 level
0.0~249.9%, 250.0:Disabled
0.1/0.01
250.0
Enabled
●
/
●
●
/
●
●
-
6. 25. 1
0444
Power running torque limit 2
level
0.0~249.9%, 250.0:Disabled
0.1/0.01
250.0
Enabled
●
/
●
●
/
●
●
-
6. 25. 1