E6581442
F-56
6
<Basic operating>
Step Setting
Parameter
1
Set the pattern operation selection
parameter at “Enabled.”
=
(Disabled)
(Pattern operation enabled, setting in seconds)
(Pattern operation enabled, setting in minutes)
2
Set all necessary operation frequencies.
In addition, set frequencies for preset
speed operation.
~
(Preset speed operation frequencies 1~7)
~
(Preset speed operation frequencies 8~15)
(Preset speed operation mode selection)
~
(Preset speed operation frequency 1~15
operation mode)
3
Set the required operation time at each of
the set operation frequencies. Using
, select the unit of time to be set
(second or minute).
~
(Operating time at each speed)
4
Set the sequence of each speed.
This sequence following three methods.
(1) Select a run/stop operation from the
pattern operation mode.
(2) Select a pattern group, and then set
the sequence of each speed.
(3) According to the required parameter
group, select pattern operation
selection 1 or 2 from input terminal
function selection
to
.
Selecting pattern operation
continuation signals makes it possible
to select a start/stop method.
=
(Patterned operation canceled during stop)
* Pattern operation is reset by stop/switching
operation before operating restarts.
=
(Patterned operation continued during stop)
* Pattern operation is started by stop/switching
operation. The system stops temporarily on
completion of every routine, then proceeds to the
next routine.
(Number of repetitions of pattern group 1)
~
(Pattern group 1 selection 1~8)
(Number of repetitions of pattern group 2)
~
(Pattern group 2 selection 1~8)
~
=
,
(Pattern operation selection 1)
=
,
(Pattern operation selection 2)
=
,
(Pattern operation continuation
signal)
=
,
(Pattern operation trigger signal)
5
Monitor displayed during pattern operation
Specify the pattern operation monitor item (
to
) that you want to display as a status monitor item
(
to
). This setting makes the inverter display the pattern operating status.
Condition Marking
Specification
Pattern and pattern group
(A)
(B)
(A): Number of the pattern group
(B): Number of the pattern
Pattern group – remaining
number of repetitions
Indicates that pattern operation has been
performed 123 times.
Operation preset speed
Frequency reference with preset speed 1 data.
Remaining time of the current
pattern operation
Current pattern is finished in 1234 sec.
Operation time is set for infinity or the system is
waiting for the next step command.