05/08
Mode
Element
Sub element
Item
Subitem
Code
Sub-
code
Details
Default
value
Acceptable
value
SRAM
Contents
Proce
dure
20L/
23L/
25L
20H/
23H/
25H
08
Setting
mode
Process
Fuser
Temperature control
lower limit (at
ordinary
temperature)
Plain paper
2205
1
Side thermistor
5
0-12
M
0: 130 degrees C 1: 135 degrees C 2: 140 degrees C 3:
145 degrees C 4: 150 degrees C 5: 155 degrees C 6:
160 degrees C 7: 165 degrees C 8: 170 degrees C 9:
175 degrees C 10: 180 degrees C 11: 185 degrees C
12: 120 degrees C
4
Y
Y
08
Setting
mode
Process
Fuser
Temperature control
lower limit (at Low
temperature)
Plain paper
2206
0
Center thermistor
7
0-12
M
0: 130 degrees C 1: 135 degrees C 2: 140 degrees C 3:
145 degrees C 4: 150 degrees C 5: 155 degrees C 6:
160 degrees C 7: 165 degrees C 8: 170 degrees C 9:
175 degrees C 10: 180 degrees C 11: 185 degrees C
12: 120 degrees C
4
Y
Y
08
Setting
mode
Process
Fuser
Temperature control
lower limit (at Low
temperature)
Plain paper
2206
1
Side thermistor
5
0-12
M
0: 130 degrees C 1: 135 degrees C 2: 140 degrees C 3:
145 degrees C 4: 150 degrees C 5: 155 degrees C 6:
160 degrees C 7: 165 degrees C 8: 170 degrees C 9:
175 degrees C 10: 180 degrees C 11: 185 degrees C
12: 120 degrees C
4
Y
Y
08
Setting
mode
Process
Fuser
Temperature control
lower limit
OHP film
2207
0
Center thermistor
7
0-12
M
0: 130 degrees C 1: 135 degrees C 2: 140 degrees C 3:
145 degrees C 4: 150 degrees C 5: 155 degrees C 6:
160 degrees C 7: 165 degrees C 8: 170 degrees C 9:
175 degrees C 10: 180 degrees C 11: 185 degrees C
12: 120 degrees C
4
Y
Y
08
Setting
mode
Process
Fuser
Temperature control
lower limit
OHP film
2207
1
Side thermistor
5
0-12
M
0: 130 degrees C 1: 135 degrees C 2: 140 degrees C 3:
145 degrees C 4: 150 degrees C 5: 155 degrees C 6:
160 degrees C 7: 165 degrees C 8: 170 degrees C 9:
175 degrees C 10: 180 degrees C 11: 185 degrees C
12: 120 degrees C
4
Y
Y
08
Setting
mode
Process
Fuser
Temperature control
lower limit
Thick paper
1
2208
0
Center thermistor
8
0-12
M
0: 130 degrees C 1: 135 degrees C 2: 140 degrees C 3:
145 degrees C 4: 150 degrees C 5: 155 degrees C 6:
160 degrees C 7: 165 degrees C 8: 170 degrees C 9:
175 degrees C 10: 180 degrees C 11: 185 degrees C
12: 120 degrees C
4
Y
Y
08
Setting
mode
Process
Fuser
Temperature control
lower limit
Thick paper
1
2208
1
Side thermistor
6
0-12
M
0: 130 degrees C 1: 135 degrees C 2: 140 degrees C 3:
145 degrees C 4: 150 degrees C 5: 155 degrees C 6:
160 degrees C 7: 165 degrees C 8: 170 degrees C 9:
175 degrees C 10: 180 degrees C 11: 185 degrees C
12: 120 degrees C
4
Y
Y
08
Setting
mode
Process
Fuser
Temperature control
lower limit
Thick paper
2
2209
0
Center thermistor
11
0-12
M
0: 130 degrees C 1: 135 degrees C 2: 140 degrees C 3:
145 degrees C 4: 150 degrees C 5: 155 degrees C 6:
160 degrees C 7: 165 degrees C 8: 170 degrees C 9:
175 degrees C 10: 180 degrees C 11: 185 degrees C
12: 120 degrees C
4
Y
Y
e-STUDIO2006/2306/2506/2007/2307/2507
SELF-DIAGNOSIS CODE (03/04/05/08 CODE)
14-1-36
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved
Содержание E-STUDIO2006
Страница 14: ......
Страница 729: ......
Страница 730: ...1 11 1 OSAKI SHINAGAWA KU TOKYO 141 8562 JAPAN ...