05/08
Mode
Element
Sub element
Item
Subitem
Code
Sub-
code
Details
Default
value
Acceptable
value
SRAM
Contents
Proce
dure
23LA
23LM/
28LM
23HA/
28HA
08
Setting
mode
Process
Fuser
Temperature control
lower limit
Thick paper
2
2210
0
Center thermistor
11
0-12
M
0: 130 degrees C 1: 135 degrees C 2: 140 degrees C 3:
145 degrees C 4: 150 degrees C 5: 155 degrees C 6:
160 degrees C 7: 165 degrees C 8: 170 degrees C 9:
175 degrees C 10: 180 degrees C 11: 185 degrees C
12: 120 degrees C
4
Y
Y
Y
08
Setting
mode
Process
Fuser
Temperature control
lower limit
Thick paper
2
2210
1
Side thermistor
9
0-12
M
0: 130 degrees C 1: 135 degrees C 2: 140 degrees C 3:
145 degrees C 4: 150 degrees C 5: 155 degrees C 6:
160 degrees C 7: 165 degrees C 8: 170 degrees C 9:
175 degrees C 10: 180 degrees C 11: 185 degrees C
12: 120 degrees C
4
Y
Y
Y
08
Setting
mode
Process
Fuser
Temperature control
lower limit
Envelope
2211
0
Center thermistor
11
0-12
M
0: 130 degrees C 1: 135 degrees C 2: 140 degrees C 3:
145 degrees C 4: 150 degrees C 5: 155 degrees C 6:
160 degrees C 7: 165 degrees C 8: 170 degrees C 9:
175 degrees C 10: 180 degrees C 11: 185 degrees C
12: 120 degrees C
4
Y
Y
Y
08
Setting
mode
Process
Fuser
Temperature control
lower limit
Envelope
2211
1
Side thermistor
9
0-12
M
0: 130 degrees C 1: 135 degrees C 2: 140 degrees C 3:
145 degrees C 4: 150 degrees C 5: 155 degrees C 6:
160 degrees C 7: 165 degrees C 8: 170 degrees C 9:
175 degrees C 10: 180 degrees C 11: 185 degrees C
12: 120 degrees C
4
Y
Y
Y
08
Setting
mode
Process
Fuser
Temperature drop
switching time
setting during
printing (Center
thermistor)
2212
0
The first drop
20
0-200
M
Setting value x 5 seconds: from 0 to 1000 seconds later
4
Y
Y
Y
08
Setting
mode
Process
Fuser
Temperature drop
switching time
setting during
printing (Center
thermistor)
2212
1
The second drop
30
0-200
M
Setting value x 5 seconds: from 0 to 1000 seconds later
4
Y
Y
Y
08
Setting
mode
Process
Fuser
Temperature drop
switching time
setting during
printing (Center
thermistor)
2212
2
The third drop
40
0-200
M
Setting value x 5 seconds: from 0 to 1000 seconds later
4
Y
Y
Y
08
Setting
mode
Process
Fuser
Temperature drop
switching time
setting during
printing (Center
thermistor)
2212
3
The fourth drop
75
0-200
M
Setting value x 5 seconds: from 0 to 1000 seconds later
4
Y
Y
Y
08
Setting
mode
Process
Fuser
Temperature drop
switching time
setting during
printing (Side
thermistor)
2213
0
The first drop
4
0-200
M
Setting value x 5 seconds: from 0 to 1000 seconds later
4
Y
Y
Y
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved
14-2-37
e-STUDIO2303A/2303AM/2803AM/2309A/2809A
SELF-DIAGNOSIS CODE (03/04/05/08 CODE)
Содержание E-STUDIO2006
Страница 14: ......
Страница 729: ......
Страница 730: ...1 11 1 OSAKI SHINAGAWA KU TOKYO 141 8562 JAPAN ...