![Toshiba E-STUDIO2006 Скачать руководство пользователя страница 558](http://html.mh-extra.com/html/toshiba/e-studio2006/e-studio2006_service-manual_424141558.webp)
05/08
Mode
Element
Sub element
Item
Subitem
Code
Sub-
code
Details
Default
value
Acceptable
value
SRAM
Contents
Proce
dure
20L/
23L/
25L
20H/
23H/
25H
08
Setting
mode
Process
Fuser
Temperature drop
switching time
setting during
printing (Side
thermistor)
2213
2
The third drop
40
0-200
M
Setting value x 5 seconds: from 0 to 1000 seconds later
4
Y
Y
08
Setting
mode
Process
Fuser
Temperature drop
switching time
setting during
printing (Side
thermistor)
2213
3
The fourth drop
75
0-200
M
Setting value x 5 seconds: from 0 to 1000 seconds later
4
Y
Y
08
Setting
mode
Process
Fuser
Energy Saving
Mode
Fuser roller
temperature
2250
-
Side thermistor
0
0-13
M
0: OFF 1: 40 degrees C 2: 50 degrees C 3: 60
degrees C 4: 70 degrees C 5: 80 degrees C 6: 90
degrees C 7: 100 degrees C 8: 110 degrees C 9: 120
degrees C 10: 130 degrees C 11: 140 degrees C 12:
150 degrees C 13: 160 degrees C
1
Y
Y
08
Setting
mode
Process
Fuser
2282
-
Pre-running time for
first printing (Envelope)
10
0-15
M
0: Invalid 1: 1sec 2: 2sec 3: 3sec 4 : 4sec 5: 5sec 6:
6sec 7: 7sec 8: 8sec 9: 9sec 10: 10sec 11: 12sec
12: 14sec 13: 16sec 14: 18sec 15: 20sec
1
Y
Y
08
Setting
mode
Process
2827
-
Developer bias AC
control ON/OFF
1
0-2
M
0: ON 1: ON-OFF 2: OFF
1
Y
Y
08
Setting
mode
Process
2835
-
Switching of recycled
toner saving control
0
0-1
M
0: Switched 1: Not switched
1
Y
Y
08
Setting
mode
Process
2837
-
Correction by
temperature/humidity
0
0-3
M
Sets the correction by temperature/humidity.
0: All valid
1: All invalid
2: Valid only in auto-toner sensor
3: All valid except separation
1
Y
Y
08
Setting
mode
Process
Developer
Developer bias
Hi1correction
(Normal)
PCL
2920
0
PRT
128
0-255
M
Compensation value: GAP from 128 is given to an
execution value
4
Y
Y
08
Setting
mode
Process
Developer
Developer bias
Hi1correction
(Toner saving
mode)
2920
1
PRT
128
0-255
M
Compensation value: GAP from 128 is given to an
execution value
4
Y
Y
08
Setting
mode
Process
Developer
Developer bias
Hi1correction
(Normal)
2920
2
PPC
128
0-255
M
Compensation value: GAP from 128 is given to an
execution value
4
Y
Y
e-STUDIO2006/2306/2506/2007/2307/2507
SELF-DIAGNOSIS CODE (03/04/05/08 CODE)
14-1-38
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved