ERROR CODE AND TROUBLESHOOTING
8 - 44
8.3.8
Drive system related service call
[C010] Main motor is abnormal
Classification
Error content
Drive system related service call
Main motor is abnormal
Proce
dure
Check item
Result
Measure
Next
Step
1
Is the main motor
working? (Perform the
output check in the test
mode: 03-101/151)
Yes
2
No
1. Check if the connector CN1 of the main
motor is disconnected.
2. Check if the connector CN19 on the MAIN
board is disconnected.
3. Check if the connector pins are
disconnected and the harnesses are open
circuited.
4. Check if the conductor patterns on the main
motor board and MAIN board are short
circuited or open circuited.
5. Replace the main motor.
2
Are there any damage or
scratches on the main
motor board?
Yes
3
No
1. Check if the connector pins are
disconnected and the harnesses are open
circuited.
2. Check if the conductor patterns on the main
motor board and MAIN board are short
circuited or open circuited.
3. Replace the main motor.
3
MAIN board
1. Check if the PLL lock signal CN19-7 output
from the MAIN board is always level “L”?
2. Replace the MAIN board.
Parts to be replaced