05/08
Mode
Element
Sub element
Item
Subitem
Code
Sub-
code
Details
Default
value
Acceptable
value
SRAM
Contents
Proce
dure
20L/
23L/
25L
20H/
23H/
25H
08
Setting
mode
Process
Fuser
Temperature drop
switching time
setting during
printing (Side
thermistor)
Thick paper
2199
2
The third drop
40
0-200
M
Setting value x 5 seconds later: from 0 to 1000 seconds
4
Y
Y
08
Setting
mode
Process
Fuser
Temperature drop
switching time
setting during
printing (Side
thermistor)
Thick paper
2199
3
The fourth drop
75
0-200
M
Setting value x 5 seconds: from 0 to 1000 seconds later
4
Y
Y
08
Setting
mode
Process
Fuser
Temperature drop
setting during
printing (Center
thermistor)
Thick paper
2200
0
The first drop
1
0-10
M
Setting value x -5 degrees C: from 0 degrees C to -50
degrees C
4
Y
Y
08
Setting
mode
Process
Fuser
Temperature drop
setting during
printing (Center
thermistor)
Thick paper
2200
1
The second drop
2
0-10
M
Setting value x -5 degrees C: from 0 degrees C to -50
degrees C
4
Y
Y
08
Setting
mode
Process
Fuser
Temperature drop
setting during
printing (Center
thermistor)
Thick paper
2200
2
The third drop
2
0-10
M
Setting value x -5 degrees C: from 0 degrees C to -50
degrees C
4
Y
Y
08
Setting
mode
Process
Fuser
Temperature drop
setting during
printing (Center
thermistor)
Thick paper
2200
3
The fourth drop
3
0-10
M
Setting value x -5 degrees C: from 0 degrees C to -50
degrees C
4
Y
Y
08
Setting
mode
Process
Fuser
Temperature drop
setting during
printing (Side
thermistor)
Thick paper
2201
0
The first drop
2
0-10
M
Setting value x -5 degrees C: from 0 degrees C to -50
degrees C
4
Y
Y
08
Setting
mode
Process
Fuser
Temperature drop
setting during
printing (Side
thermistor)
Thick paper
2201
1
The second drop
3
0-10
M
Setting value x -5 degrees C: from 0degrees C to -50
degrees C
4
Y
Y
08
Setting
mode
Process
Fuser
Temperature drop
setting during
printing (Side
thermistor)
Thick paper
2201
2
The third drop
4
0-10
M
Setting value x -5 degrees C: from 0 degrees C to -50
degrees C
4
Y
Y
08
Setting
mode
Process
Fuser
Temperature drop
setting during
printing (Side
thermistor)
Thick paper
2201
3
The fourth drop
5
0-10
M
Setting value x -5oC: from 0
o
C to -50oC
4
Y
Y
08
Setting
mode
Process
Fuser
Temperature control
lower limit (at
ordinary
temperature)
Plain paper
2205
0
Center thermistor
7
0-12
M
0: 130 degrees C 1: 135 degrees C 2: 140 degrees C 3:
145 degrees C 4: 150 degrees C 5: 155 degrees C 6:
160 degrees C 7: 165 degrees C 8: 170 degrees C 9:
175 degrees C 10: 180 degrees C 11: 185 degrees C
12: 120 degrees C
4
Y
Y
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved
14-1-35
e-STUDIO2006/2306/2506/2007/2307/2507
SELF-DIAGNOSIS CODE (03/04/05/08 CODE)
Содержание E-STUDIO2006
Страница 14: ......
Страница 729: ......
Страница 730: ...1 11 1 OSAKI SHINAGAWA KU TOKYO 141 8562 JAPAN ...