ERROR CODE AND TROUBLESHOOTING
8 - 88
8.4.21
Uneven light distribution
Fig.8-23
Defective area
Step
Check items
Prescription
Original glass
1
Is the original glass dirty?
Clean the original glass.
Main charger
2
Are the needle electrode, main
charger grid and main charger case
dirty?
Clean or replace them.
Discharge LED
3
Is the discharge LED dirty?
Clean the discharge LED.
4
Is any of the discharge LEDs off?
Replace the discharge LED.
Scanner
5
Are the original glass (especially the
position of shading correction plate)
and CIS unit dirty?
Clean them.
Exposure lamp
6
Is the CIS unit degraded?
Replace the CIS unit.
Feeding direction